ZEUS-VD INSTALLER’S MANUAL
Programming table for ZEUS4-VD Set-up parameters
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
CRE
3
Number of dialing attempts (1 – 99)
HTN
1
Hidden telephone number (1= displayed, 0 = hidden)
RAN 5
Number of rings before answering
SCV
for prepay SIM
SIM card time validity from 1-360 in days
MNF
Automatic network searching (default)
LNG 0
Switch between different languages’
TST
Periodic test SMS - disabled
Example:
We’d like to change set-up parameters with following values:
ZEUS4-VD - GSM PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
CRE
2
Number of dialing attempts - 2
HTN
0
Hidden telephone number of the ZEUS4-VD
RAN 5
The unit will answer after 5 rings
SCV
360
Refill time is 360 days
MNF
29340
Manual fixing of the GSM provider (Simobil)
LNG 1
Switch on Italian language
TST
24
24 hours periodic test SMS
9.16.1
Set-up parameters programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;CRE=2;HTN=0;SCV=360;MFN=29340;TST=24;RAN=5;
If you want to get the confirmation SMS back then write “
+
” before SMS command:
;+CRE=2;HTN=0;LPA=360;MFN=29340;TST=24;RAN=5;