ZEUS-VD INSTALLER’S MANUAL
TC1
3 1
st
CLIP will make the Output 3 activate
TC2
5 2
nd
CLIP will make system OFF/ON
TC3
6 3
rd
CLIP will make a call back from device to user
9.11.2
TC parameter remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;TC1=3;TC2=5;TC3=6;
If you want to get the confirmation SMS back then write “
+
” before SMS command:
;+TC1=3;TC2=5;TC3=6;
9.12
INPUT TIME WINDOW – IT
The IT parameter determinate the time window within we can trigger (n) alarms (programmed by
AR parameter) before the input will automatically blocks. After the IT time the input will be setting
free and it will start counting alarm triggers (AR) again. The IT value can be from 1 - 9999 seconds.
For example:
Programming table for the input time window – IT
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number (Default)
Description
IT1 180
Default value for time window is 180 seconds
IT2
180
Default value for time window is 180 seconds
IT3
180
Default value for time window is 180 seconds
IT4
180
Default value for time window is 180 seconds
Example:
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
NAME
NUMBER
DESCRIPTION
IT1 20
Time window is set on 20 seconds
IT2
75
Time window is set on 75 seconds
IT3
180
Time window is set on 180 seconds
IT4
900
Time window is set on 900 seconds
9.12.1
The input time window remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4:
;IT1=20;IT2=75;IT3=180;IT4=900;
Page 21