ZEUS-VD INSTALLER’S MANUAL
9.13
INPUT TRIGGER COUNTER BEFORE BLOCK - AR
With AR parameter you can program the numbers of the alarm triggers in the time programmed by
IT parameter. After (n) alarm triggers in programmed time IT the input will block automatically and
will stop calling and sending the alarm SMS.
Programming table for the input trigger counter – AR
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number (Default)
Description
AR1 5
Default is 5 alarm triggers before input has been blocked
AR2 5
Default is 5 alarm triggers before input has been blocked
AR3 5
Default is 5 alarm triggers before input has been blocked
AR4 5
Default is 5 alarm triggers before input has been blocked
Example:
ZEUS4-VD PROGRAMMING TABLE
SIM CARD PHONE BOOK
NAME
NUMBER
DESCRIPTION
AR1 3
The Input has been blocked after 3 alarm triggers
AR2 10
The Input has been blocked after 10 alarm triggers
AR3 10
The Input has been blocked after 10 alarm triggers
AR4 30
The Input has been blocked after 30 alarm triggers
9.13.1
The input trigger counter before block remote programming by SMS
For the upper example send the following SMS from the host phone to the ZEUS4-VD:
;AR1=3;AR2=10;AR3=10;AR=30;
If you want to get the confirmation SMS back then write “
+
” before SMS command:
;+ AR1=3;AR2=10;AR3=10;AR=30;