3
OODMANUAL 0720
KAM CONTROLS, INC.
2 S P E C I F I C AT I O N S
Minimum Range:
0-100*
Maximum Range:
0-5000 ppm*
Accuracy:
0-500 ppm and higher ± 1% of full range
Below 0-500 ppm, minimum resolution of 5 ppm
Material:
Wetted parts–316 stainless steel, other materials available
Power:
12–24 VDC 5 Watts max, 110/220 AC available with adapter
Output:
4-20
mA
RS485
Modbus
HART
(optional)
(1)
High-current
output
(alarm/digital
out)
Fluid temperature:
-40º to 176ºF (-40º to 80ºC)
Electronics temp.:
-4º to 140ºF (-20º to 60ºC)
Pressure ratings:
ANSI 150, 300, 600, 900
Threaded models (3/4", 1" MNPT) designed maximum working pressure of 2100 psig
Mounting:
2" MNPT seal housing
2", 3", or 4" flanged seal housing
3/4", 1" MNPT for analyzer loops
EX enclosure:
3" x 6" x 3" (76 mm x 152 mm x 76 mm)
Protection:
NEMA 4X
Shaft length:
Off-the-shelf lengths are 20", 24", 30", 36" (508 mm, 609.6 mm, 762 mm, 914.4 mm)
Additional
sizes
available
Pipe size:
3/4" to 48"
Weight:
from 10 lbs. (4.5 kg)
* Range and accuracy are hydrocarbon dependent. Some applications/hydrocarbons may require lab samples for
testing in order to determine allowable range and accuracy.