EIASMANUAL 0918
KAM CONTROLS, INC.
8
9.
If you have an E-IAS™ Sampler with a Flanged Seal Housing, you may now attach it to the Valve on the pipeline.
Slowly open Full Opening Valve and check for leaks.
Loosen Hex Socket Cap Screw on the Locking Collar.
Align Window of the E-IAS™ Sampler to face the flowing stream. This can be done by aligning the Flow
Indicators in parallel with the main pipe. The Flow Indicators are located at the bottom of the Actuator
Housing.
Push the E-IAS™ Sampler in until the Second Mark is at the top edge of the Locking Collar. Fig. 3-8.
10.
11.
12.
13.
14.
I N S TA L L AT I O N C O N T I N U E D
FIG. 3-8
FIG. 3-7
First Mark
Second Mark
TID
Second Mark
For all insertable models, use the calculated TID and make another mark on the shaft, measuring from
First Mark. Fig 3-7.