KAM CONTROLS, INC.
5
Full-opening
Ball Valve
Hex socket cap screws
FIG. 3-2
In horizontal lines, the E-IAS™ Sampler should be installed with the probe horizontally oriented at 3 or 9 o’clock.
Fig. 3-2.
The E-IAS™ Sampler Probe should be inserted so that the middle of the sampling window is in the 20% center area
of the pipe. Fig. 3-2. It is the user’s responsibility to ensure that the E-IAS™ Sampler is placed in the most represen-
tative point in the flow profile.
Insertable models of the E-IAS™ Sampler should be installed according to Fig. 3-2. The Full-Opening Ball Valve is
used to isolate the E-IAS™ Sampler from the pipeline during installation or removal. The Seal Housing of the E-IAS™
Sampler allows the Sampler Probe to be inserted in and out of the pipe under pressure and flow conditions up to 100
psi.
INSERTABLE/RETRACTABLE MODELS INSTALLATION
I N S TA L L AT I O N
Before mounting the E-IAS™ Sampler on the Full-Opening Ball Valve, determine the insertion length required.
Lay the E-IAS™ Sampler on the ground or a table.
Loosen Hex Socket Cap Screws on the Locking Collar using a 3/8" Allen wrench. Fig. 3-2. This will allow the E-
IAS™ Sampler Shaft to slide through the Seal Housing.
Push the E-IAS™ Sampler Shaft though the Seal Housing until the middle of the sampler window chamber is
aligned with the end of the Seal Housing. Fig. 3-3.
Use a Sharpie or other permanent marker to mark the shaft at the edge of the Locking Collar. (Do not use any-
thing sharp to mark the shaft. This will create grooves that will damage the O-rings in the Seal Housing.)
1.
2.
3.
4.
FIG. 3-3
FIG. 3-4
Mark Here
Align
here