Rotating rotors!
Danger of squashing or severing of extremities especially fingers.
➤ Do not reach into the interior of the block.
Moisture and frost can damage the machine!
➤ Prevent ingress of moisture and formation of condensation.
➤ Store the machine in a dry, frost-proof room.
➤ Protect the flange connections, drive shaft and delivery space of the block by spraying with ap‐
propriate an conservation oil, e.g., ANTICORIT OHK.
➤ Seal off the inlet and discharge ports to prevent entry of dirt.
➤ Each month, manually turn the motor shaft by about 30°.
➤ Change the lubricating oil annually.
After lengthy storage
➤ Remove the preservative from the flow chamber with cleaning solvent.
➤ Observe the procedures for assembly and initial start-up.
➤ Change the lubricating oil.
➤ Re-grease the drive motor bearings if they are not of the permanently greased type.
➤ Check the condition and tension of the drive belts.
12.5 Disposal
When disposing of a machine, drain out all liquids and remove old filters.
Precondition The machine is decommissioned.
1. Completely drain the oil from the machine.
2. Remove old filters.
3. Hand the machine over to an authorized disposal expert.
➤ Components contaminated with oil must be disposed of in accordance with local environ‐
mental protection regulations.
12 Decommissioning, Storage and Transport
12.5 Disposal
88
Installation and Operating Manual Rotary lobe blower
HBPI pr
Number: 9_9572 28 USE