Feature
Data
Cable connection
up to 2.5 mm
2
(AWG 14)
Tab. 17 Speed monitoring device (Option C10)
Sensor setting
Feature
Data
Display format
DIM=0 (rpm)
Number of control caps, input 1
NC1=2
Memory function outputs 1 and 2
SO1=0 (inactive) SO2=0 (inac‐
tive)
Switching function outputs 1 and 2
Analogue starting value for analogue output 3 [mA]
FO1=2
FO2=3
AO3=4.0
Switching point outputs 1 and 2 [rpm]
Analogue starting value for analogue output 3 [rpm]
SP1=500
SP2=1000
FA3=1000
Hysteresis for switching points 1 and 2 [%]
HY1=3
HY2=5
Start override time outputs 1 and 2 [s]
ST1=60.0
ST2=0.0
Delay time outputs 1 and 2 [s]
DT1=10.0
DT2=0.0
Wiping function outputs 1 and 2 [s]
FT1=0.0
FT2=0.0
Tab. 18 Setting of the speed monitor evaluation device (Option C10)
Further information The wiring diagram for Option C10 in chapter 13.6 contains further details of the power supply con‐
nection.
2.14.4 Option C11
Unloaded start valve (AFE)
Model
AFE 90
AFE 150
Permissible pressure
[psig] (a)
0 – 29
0 – 29
Maximum flow rate [cfm]
3178
5297
Nominal size
(DIN ISO 228–1)
Flange DN 150 PN 10
Flange DN 200 PN 10
Tab. 19 Unloaded start valve (AFE)
2.14.5 Option C13
Temperature gauge switch
Feature
Data
Switching capacity at
250 V(AC) [A]
Single pole micro-switch with
changeover contact
Inductive load
1.5
Resistive load
5.0
Switching differential of the scale range [%]
<3
2
Technical Data
2.14 Options
Number: 9_9572 28 USE
Installation and Operating Manual Rotary lobe blower
HBPI pr
11