Description
Figure
Instrument weather protection
34
= 831469.0
➤ Install the weather protection for the instru‐
ments
34
at the instrument corner panel,
using blind rivet nuts and hex-head screws.
Tab. 34 Sound enclosure assembly (Option H12)
Connecting elements
Fig. 30 Connecting elements
50
Hex-head screw, M6x16 stainless
51a
Plastic dowel SX16
51b
Hexagon wood screw, galvanised 12x80
51c
Washer 12, galvanised
52
Countersunk nut 8x20, stainless steel
53
Hex-head screw M8x60 stainless
54
Hex-head screw M8x100 stainless
55
Hexagon screw cap
56
Hinge, left
57
Hinge, right
➤ For questions, please contact an authorized KAESER service representative.
6.10.11.3 Connecting the ventilator fan
The fan motor has a terminal box for direct supply connection.
The drive motor and the fan must run simultaneously.
Ensure correct direction of rotation when connecting the fan. The fan must blow air out of the
sound enclosure.
The fan should run on for approximately 15 minutes after machine shut down to avoid temperature
peaks inside the sound enclosure.
Precondition The power supply is switched off,
The device is locked off,
A check has been made that no voltage is present.
1. Select sufficient cable length.
6
Installation
6.10 Options
Number: 9_9572 28 USE
Installation and Operating Manual Rotary lobe blower
HBPI pr
55