Fig. 13 Install the venting valve on-site
1
Venting valve on the pressure switch
2
Venting valve (solenoid valve) at the compressed air discharge point
1. DANGER!
Dangerous voltage!
There is danger of fatal injury caused by contact with live components.
➤ Switch off and lock out the power supply disconnecting device and check that no voltage
is present.
2. WARNING!
Serious injury or death can result from loosening or opening components under pressure.
➤ De-pressurise all pressurised components and enclosures. Verify pressure-free status.
3. Install the venting valve either on the pressure switch, or at the machine's compressed air dis‐
charge point.
6.7 Installation examples
The following installation examples are suggestions only and do not relate directly to a specific ap‐
plication.
6.7.1 Safety and Control Devices
Safety and regulating devices ensure safe machine operation.
6
Installation
6.7
Installation examples
38
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753 24 E