➤ Use suitable lifting gear that conforms to local safety regulations.
➤ Allow transportation only by personnel trained in the safe movement of loads.
➤ Attach lifting gear only to suitable lifting points.
➤ Be aware of the centre of gravity to avoid tipping.
➤ Ensure the danger zone is clear of personnel.
➤ Do not step onto machine components to climb up the machine.
Assembly
➤ Use only electrical cables that are suitable and approved for the surroundings and electrical
loads applied.
➤ Never dismantle compressed air pipes until they are fully vented.
➤ Only use pressure lines that are suitable and approved for the maximum working pressure and
the intended medium.
➤ Do not allow connection pipes to be placed under mechanical stress.
➤ Do not induce any forces into the machine via the connections, so that the compressive forces
must be balanced by bracing.
Installation
A suitable installation location for the machine prevents accidents and faults.
➤ Install the machine in a suitable compressor room.
➤ Ensure sufficient and suitable lighting such that the display can be read and work carried out
comfortably and safely.
➤ Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
➤ If installed outdoors, the machine must be protected from frost, direct sunlight, dust, rain and
splashing water.
➤ Do not operate in areas in which specific requirements with regard to explosion protection are
in force.
For instance, the requirements of ATEX directive 2014/34/EC "Equipment and Protective Sys‐
tems intended for use in Potentially Explosive Atmospheres".
➤ Ensure adequate ventilation.
➤ Place the machine in such a manner that the working conditions in its environment are not im‐
paired.
➤ Comply with limit values for ambient temperature and humidity.
➤ The intake air must not contain any damaging contaminants.
Damaging contaminants are for instance: explosive or chemically instable gases and vapours,
acid or base forming substances such as ammonia, chlorine or hydrogen sulfide.
➤ Do not position the machine in the warm exhaust air flow from other machines.
➤ Keep suitable fire extinguishing agents ready for use.
Commissioning, operation and maintenance
During commissioning, operation and maintenance you may be exposed to dangers resulting from,
e.g., electricity, pressure and temperature. Careless actions can cause accidents with severe ad‐
verse effects for your health.
➤ Allow maintenance work to be carried out only by authorised personnel.
➤ Wear close-fitting, flame-resistant clothing. Wear protective clothing as necessary.
3
Safety and Responsibility
3.6
Dangers
20
Assembly and operating manual 2-stage piston compressor
EPC-2-G
No.: 9_5753 24 E
Содержание EPC 150-2-G
Страница 2: ...KKW PEPC 2 04 en SBA KOLBEN AGGREGAT 2 STUFIG 20170303 120300...
Страница 6: ...Contents iv Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 10: ...List of Tables viii Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...
Страница 100: ...13 Annex 13 2 Dimensional Drawing 90 Assembly and operating manual 2 stage piston compressor EPC 2 G No 9_5753 24 E...