Installing the inverter
Page 24
Installation Instructions KACO
blueplanet
32.0 TL3 / 40.0 TL3 / 50.0 TL3
NOTICE
Diff erent manufacturers do not always interpret the standard on which the RS485 protocol is based in the
same way. Note that the wire designations (DATA- and DATA+) for wires A and B may vary from one manu-
facturer to another.
NOTICE
Calculating effi
ciency by measuring the current and voltage values can lead to misleading results due to
the tolerances of the measurement devices. The sole purpose of these measured values is to monitor the
basic operation of the system.
7.4.5.1 Wiring
diagram
1
2
2
3
4
5
Figure 18: RS485 interface wiring diagram
Key
1
Inverter, terminal unit
4
Communication
2
Inverters
5
230 V AC
3
data logger
Properties of the RS485 data line
Maximum length of the RS485
bus line
The maximum allowed length of the RS485 bus is 1200 m.
This length can be reached only under optimum conditions.
Lengths exceeding 500m generally require a repeater or a hub.
Maximum number of
connected bus devices
31 inv 1 data monitoring unit
Data line
Twisted, shielded. Recommendations:
LI2YCYv (twisted pair) black for laying cable outside and in the ground, 2 x 2 x 0.5
LI2YCY (twisted pair) grey for dry and moist indoor spaces, 2 x 2 x 0.5
Содержание blueplanet 40.0 TL3