prevent user credential validation and so the 
lock will deny access to keypad 
programming modes (like date/time setting). 

Enter communication mode by typing: 

o

 900# 

The green led blinks with high pitch sound to 
confirm the command and then red and 
green leds blink in alternate sequence to 
indicate communication mode is activated.   
 
The communication with the maintenance 
unit must be established within 15 seconds 

 

Click ‘Send’ on the maintenance unit ‘Set 
Time’ dialog 

Once the time is set, an ‘ok’ dialog box will 
be displayed and the lock will respond with a 
high pitch sound. 

 

Configure the lock using the admin card 

 

 

Enter the lock configuration command 
(where valid users will be transferred to 
lock via the Admin card): 

o

 100# 

The green led will blink to indicate that it is 
waiting for the Admin card. 

 

Present the Admin card to the lock 

Once the lock reads and processes the 
Admin card, the green led will turn on with a 
high pitch sound indicating success. 
 
[After exiting the keypad programming mode 
as shown on the next step, the lock is now in 
(user credential) access mode. A valid ISO 
14443A DESFire user card will now operate 
the lock]. 

 

Exit keypad programming mode 

Either exit pressing the ‘#’ key or leave the 
lock idle for five seconds.  In the latter case, 
the red led turns on with a low pitch sound to 
indicate a timeout. 

 

Press ‘#’ key 

Green led blinks with high pitch sound 

 

16.2  In Access mode 

 

Step 

Sub 

Description/Operation 

Notes 

 

Enter lock keypad programming. 

 

 

1.1 

Start keypad programming mode 

o

  Press ‘#’ key 

 

 

 

1.2 

If the lock is configured for PIN and card: 

o

  Type in PIN 

o

  Press ‘#’ key 

 

 

 

1.3 

Present a valid user card having ‘update 
using admin card’ privilege to the lock 

If programming mode is entered, the green 
led turns on along with a high pitch sound. 

 

Configure the lock using the admin card 

 

 

Enter the lock configuration command 
(where valid users will be transferred to 
lock via the Admin card): 

o

 100# 

If the user does not have the ‘update using 
admin card’ privilege, access will be denied 
(red led low pitch sound).  The green led will 
blink to indicate that it is waiting for the 

Содержание E-Plex 5900

Страница 1: ...E Plex 5900 Card Connect Lock User Guide Beta Version June 2007...

Страница 2: ...an be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Incre...

Страница 3: ...UNLOCK OPTION 10 10 DOOR AJAR SENSING OPTION 10 11 RESETTING THE LOCK TO FACTORY DEFAULTS 10 12 MECHANICAL KEY OVERRIDE 10 13 LOCK KEYPAD COMMANDS 11 13 1 ENTERING KEYPAD PROGRAMMING MODE 11 13 2 EXIT...

Страница 4: ...4 37 4 17 QUICK LOCK UPDATE 23 17 1 FIRMWARE UPDATE 23 17 2 BOOTLOADER UPDATE 24 APPENDIX 25...

Страница 5: ...d in a Card Connected on line headend system For quick start jump straight to the Quick lock configuration and the Quick lock update sections of the manual starting from page 19 1 1 Scope The document...

Страница 6: ...ootloader 3 1 Factory mode Out of the box the lock is in factory mode with a lock function as Entry and with an 8 digit PIN to open the lock as 12345678 This mode provides the operator with a known in...

Страница 7: ...f the following keypad commands o Set date and time requires keypad programming privilege o Set passage mode requires passage mode privilege o Configure the lock using an admin card requires admin car...

Страница 8: ...figured in pin and card mode 1 Type in pin 2 Present card If the lock is configured in card only mode 1 Present card Note that in card only access the lock allows the user to enter his pin first also...

Страница 9: ...cy override privilege Turning the thumbturn in the horizontal position activates privacy and locks the lock Privacy activation deactivates passage mode and also locks the lock The privacy unlock optio...

Страница 10: ...indicate occurrences of these events an alternate red and green flash sequence for an egress a double green led flash when door is opened from outside and a double red led flash when it is closed 11 R...

Страница 11: ...lable IF the related privileges are granted see table below The following table lists the privileges required to access keypad commands These privileges are REQUIRED once the lock is configured using...

Страница 12: ...ng sequence where the PIN must be 8 digits in length PIN Where PIN is the construction pin which must be different from the factory pin Access If the lock was configured for pin and card enter the fol...

Страница 13: ...deactivate passage mode 399 A Where A is 1 activate or 0 deactivate Activate deactivate lockout 499 A Where A is 1 activate or 0 deactivate Perform diagnostics 500 None When this command is entered t...

Страница 14: ...ssion 900 None The red and green leds blink in alternate sequence indicating ready for communications with the M Unit until one of the following occurs No connection is established during a 15 seconds...

Страница 15: ...ndows Mobile PDA The E Plex 5900 M Unit can be used to perform the following functions Setting Date Time Parameters Setting Communications Key Updating Lock Firmware Performing Lock Diagnostics Import...

Страница 16: ...rence between local standard time and UTC and is not adjusted for DST Example set 5 for Eastern Standard Time When this function is activated the application will display the last saved settings if th...

Страница 17: ...M Unit application itself but by the headend system and the M Unit operator must enter these numbers at the initial M Unit setup The M Unit will simply pass these pre set values to the lock in order t...

Страница 18: ...is no change to the bootloader it is perfectly acceptable to simply update the firmware file using the existing bootloader Important In order to perform a firmware upload the lock must be placed unde...

Страница 19: ...continuous loop diagnostics at this time 15 Audit Logs The E Plex 5900 keeps a log entry for every transaction or event encountered in its memory The audit log entries are stored in a circular list wh...

Страница 20: ...ed by pressing the key followed by the default PIN and then pressing again Any command will exit back to keypad programming mode if the lock is idle for 5 seconds The keypad programming mode is itself...

Страница 21: ...ound indicating success After exiting the keypad programming mode as shown on the next step the lock is now in user credential access mode A valid ISO 14443A DESFire user card will now operate the loc...

Страница 22: ...programming mode as shown on the next step the lock now goes back to user credential access mode A valid ISO 14443A DESFire user card will now operate the lock 3 Exit keypad programming mode Either ex...

Страница 23: ...lue of 16 zeros Otherwise the key is whatever value was configured in the admin card 4 Select the FW update option 2 Set the lock in communication mode 1 From construction mode 1 1 Enter keypad progra...

Страница 24: ...firmware mode and ready for use Should the lock reply with an Invalid bootloader the bootloader must first be updated 17 2 Bootloader update The bootloader can only updated when the lock firmware is r...

Страница 25: ...red and green blink in sequence to indicate communication mode is activated The communication with the maintenance unit must be established within 15 seconds 2 5 Skip to step 3 3 Start bootloader uplo...

Страница 26: ...PC PPC Microsoft ActiveSync Version 4 5 or greater Windows Mobile Device Center installed on your and running Microsoft Windows XP Vista Operating System Overview The E Plex 5900 M Unit Maintenance U...

Страница 27: ...0 M Unit insert the installation CD and wait for the installation application to automatically begin If this feature is disabled in the PC explore the CD and click on autorun exe The following screen...

Страница 28: ...28 37 28 Accept the default destination folder to install the PC portion of the E Plex 5900 M Unit software or click on Browse and select your desired folder...

Страница 29: ...29 37 29 Click on Next to continue Click on Install You will see the following screen messages...

Страница 30: ...on your Windows Mobile device The list includes Kaba E Plex 5900 and Microsoft NET CF 2 0 which you must install and any other applications that need to be installed on the WM device It is important t...

Страница 31: ...31 37 31 Click on OK to start the actual installation process as shown in the following screen Finally the following prompt will be displayed...

Страница 32: ...on your Mobile device You may see the following prompt If this prompt is displayed select Yes You will then see the following screen as the E Plex 5900 M Unit software including Microsoft NET Compact...

Страница 33: ...t application is now installed on your PPC and is ready to use To run the E Plex 5900 M Unit program on the PPC click on Start then Programs and select and click on the application icon EPlex5900 For...

Страница 34: ...Plex 5900 M Unit will not uninstall completely if you attempt to remove it via the ActiveSync interface Ensure that your WM device is connected to your PC and is turned on From the PC Control Panel op...

Страница 35: ...e device Note that checked items will not be uninstalled Uncheck Kaba E Plex 5900 and Microsoft NET CF 2 0 in order to completely uninstall the E Plex 5900 M Unit application Click on the Remove butto...

Страница 36: ...36 37 36 Click OK to continue You will again see the following screen Ensure that Kaba E Plex 5900 is unchecked to uninstall and select OK...

Страница 37: ...n is fully removed you will see the following confirmation Click on Finish to end the uninstall operation Kaba Access Control Tech Support Phone 800 849 8324 or 336 725 1331 x400 Monday through Friday...

Отзывы: