10/37
10
9. Remote Unlock option
(*must be installed to operate*)
If installed, the remote unlock option enables users to unlock the lock with a normally open, momentary on/off
switch. This switch is connected to the remote unlock connector inside the lock by a 24 AWG gage twisted pair
wire up to about 100 feet in length The remote unlock option must be marked as ‘enabled’ in the admin card
programmed by the headend system, otherwise the lock will not respond to the remote unlock switch.
When enabled, remote unlock can be used to unlock the door during:
Tamper
shutdown
However it will not unlock the lock:
During
lockout
[When privacy is enabled for privacy locks; ** future**]
10. Door Ajar Sensing option
(*must be installed to operate*)
If installed, the door ajar sensing option senses the door opened (and then door closed) status when opened from
outside (ingress); and also the door opened status when opened from inside (egress). In either case the door ajar
events are audited in the lock’s memory and passed on to the headend system via the admin card as logged
entries. In factory mode only, the lock will also visually indicate occurrences of these events: an alternate red and
green flash sequence for an egress, a double green led flash when door is opened from outside and a double red
led flash when it is closed.
11. Resetting the lock to factory defaults
The lock can be reset to factory defaults at any time by following this procedure.
Warning:
When a hard reset like
this is performed, all newly programmed lock configuration parameters, user access privilege policies etc will be
erased from the lock memory and the lock will default to the factory default lock parameters and the factory default
PIN of 12345678. However, the current date & time will not be altered.
1) Insert and turn mechanical override key to retract latch and hold,
2) Press key ‘#’ and release key override within 5 seconds
3) While red and green led flash alternately, press sequence ‘12345678#’ (if successful, green led
flashes twice with high pitch beep) and the lock is reset to factory defaults.
Note that audit logs are not erased by this procedure.
12. Mechanical key override
The key override is used to:
Mechanically unlock the lock (insert and turn the key to retract the latch)
Reset the lock to factory defaults (see ‘Resetting the lock to factory defaults’ section)
Reset tamper shutdown (see ‘Tamper shutdown’ section)
Deactivate lockout (see ‘lockout mode’ section)