19
Using the Micro Inverter and Optimizer Mounting Kit Hardware
from Everest Solar Systems, attach your chosen device to the top
channel of CrossRail.
Torque: 10.3 ft-lb (14 Nm).
Materials required: Micro Inverter Mounting Kit includes: M8 x 13
mm Hex Bolt, M8 lock washer, M8 flat washer, MK3
12
OPTIONAL: ATTACH MICRO INVERTERS
13
ATTACH END CLAMPS
Insert the MK3 slot nut of the pre-assembled end clamps into the
top channel on CrossRail. While slightly lifting the plastic tabs, rota-
te 90 degrees clockwise to engage the MK3 into the channel.
Attach the end clamps to the module at the specified locations per
the PV module manufacturer’s installation instructions.
Torque: 10.3 ft-lbs.
Ensure the clamp sits flush against the frame of the PV module.
Note: Never mount end clamps directly over a rail connector or at
the end of the rail. Ensure a minimum gap of 1" (20 mm) exists from
the end of the rail to the clamp.
Important: Verify module manufacturer’s recommended torque
specification to ensure clamps are compatible.
Materials required: End Clamp Set