1
Programming Reference
1.7 Machine setup menu
Page 42
Docu-No.: 0590020601-EN Rev. 1.6.0
1.7.9
Motor sub-menu for HiPo, LoPo Stepper motor
This chart is used to program the HiPo and LoPo stepper drives, part
numbers 0000004568 and 0000001430 respectively.
Parameter
Definition
GEAR REDUC
Gear Reduction or Total
Gear Reduction
This parameter if entered as the gear reduction value between the
stepper motor and the disk/screw, results in the disk/screw speed
being displayed in the parameter <SCREW SPEED>.
Input range: 0 to 999
Default: 0
PICK UP TEETH
Speed Pickup Teeth
Input of the number of pulses per revolution of the optical encoder.
This encoder is used for measuring the speed.
Input range: 0 to 9999
Default: 400
MAX MOT SPEED - [rpm]
Maximum Motor Speed
Input of the maximum motor rpm for 100% drive command.
Input range: Drive specific.
Default: 60
(See table
for values)
MDU STATUS
MDU Status
The MDU status codes reveal operational condition of the Drive. See
listing of MDU status codes in section
.
DC CEILING-[%]
Drive Command Ceiling
Limitation of the drive command output to the motordrive.
Input range: 10 to 125%
Default: 100%