(No.49879)1-19
SECTION 4
ADJUSTMENT
4.1
Test instruments required for adjustment
(1) Digital oscilloscope (100MHz)
(2) Jitter meter
(3) Digital tester
(4) Electric voltmeter
(5) Tracking offset meter
(6) Test Disc : VT501 or VT502
(7) Extension cable for check
(8) Extension studs and FFC extension cable
4.2
Standard measuring conditions
Caution:
Be sure to attach the heat sink and rear bracket onto the
power amplifier IC and regulator IC respectively, before
supply the power.
If voltage is applied without attaching these parts, the
power amplifier IC and regulator IC will be destroyed by
heat.
4.3
For comfirmation of the Main board and mechanism movements
Connecting diagram 1 of extension cable
Power supply voltage : DC14.4V(11V to 16V)
Load impedance
: 4
Ω
(2 Speakers connection)
Line output
: 20k
Ω
Main board
Extension cable
EXTGS004-26PL
Extension studs
STDV001-3P
Extension stud
STDV001-3P
Heat sink
Rear bracket
Extension cable
EXTDV001-20P