(No.YA318)1-53
5.1.6 DETAILS
SELF CHECK is performed for the following items:
5.1.7 DISPLAY METHOD WHEN RASTER IS NOT AVAILABLE
The self check results are shown on the following LED display.
Method of indication when the raster is not displayed.
Each failure is shown by turning LED on and off at the specified
intervals.
• For B1 over-current protection, CRT neck protection and Low
B short protection, the power of the TV is turned off, if NG is
detected. Immediately after the power is turned off, POWER
LED will be turning on and off. When the power is turned off,
you cannot turn the power on again until the AC plug is taken
out and put in again.
Check Item
Indication
Details of detection
Method of detection
X-ray protection
XRAY
Operation of X-ray protection circuit.
Q1853
[MAIN PWB]
At about 3 seconds after the power is turned on, the self-
check function starts.
If NG is detected for 200ms, POWER LED is turned on and off.
B1 over-current
protection
OCP
B1 over-current is detected.
Q971
[DEF & CONVERGENCE OUT PWB]
At about 3 seconds after the power is turned on, the self-check
function starts.
If NG is detected for 200ms, the power is turned off automatically.
Low B short protection
LOB
Operation of low B short protection circuit.
5V:
Q1961
9V:
Q1962
[MAIN PWB]
At about 3 seconds after the power is turned on, the self-check
function starts.
If NG is detected for 200ms, the power is turned off automatically.
CRT neck protection
Operation of CRT neck protection circuit.
Q402
[DEF & CONVERGENCE OUT PWB]
At about 3 seconds after the power is turned on, the self-check
function starts.
If NG is detected for 1.5s, the power is turned off automatically.
Timer (clock)
TIM
The power frequency is changed as follows:
50Hz
→
60Hz / 60Hz
→
50Hz
I
C1701
[MAIN PWB]
Periodically check the power frequency by counting the AC
pulse and monitor whether or not the frequency is changed
except for the time immediately after resetting.
Presence or absence
of synchronized
signal
SYNC
Presence of synchronized signal.
HD: Component input / M: NTSC main / S: NTSC sub
IC1301
[MAIN PWB]
When entering the self-check mode, "OK" is shown.
While running the mode with picture signal, if the
synchronized signal is disappeared, "NG" is shown.
Main memory
MEM
ACK is returned when I
2
C traffic is carried out.
IC1803
(memory) [MAIN PWB]
The state is monitored every time when I
2
C traffic is carried out.
Then the state is counted as a failure if ACK is not returned.
AV switch
AVSW
Ditto
IC1501
and
IC1801
[MAIN PWB]
Ditto
Video process
VCD
Ditto
IC1301
[MAIN PWB]
Ditto
Audio process
AIO
Ditto
IC1140
[MAIN PWB]
Ditto
3D YC separation
YC
Ditto
IC3101
[DIGITAL SIGNAL PWB]
Ditto
RF tuner
TUN
Ditto
TU1101
[MAIN PWB]
Ditto
Multi screen
PP
Not used
---
DIST process
IP
ACK is returned when I
2
C traffic is carried out.
IC3001
[DIGITAL SIGNAL PWB]
The state is monitored every time when I
2
C traffic is carried out.
Then the state is counted as a failure if ACK is not returned.
Digital input process
HDMI
Ditto
Ditto
Split protection
SPRT
Not used
---
Item
POWER LED ON / OFF intervals
X-ray protection
Turning on and off at 0.1-second intervals
B1 over-current protection
Turning on and off at 1-second intervals
Low B short protection
Turning on and off at 2-second intervals
CRT neck protection
Turning on and off at 3-second intervals
Содержание AV-48P776/H
Страница 1: ......
Страница 92: ... No YA318 2 4 ...
Страница 135: ...2 47 No YA318 PATTERN DIAGRAMS MAIN PWB PATTERN SOLDER SIDE ...
Страница 136: ... No YA318 2 48 FRONT ...
Страница 137: ...2 49 No YA318 MAIN PWB PATTERN PARTS SIDE ...
Страница 138: ... No YA318 2 50 FRONT ...