11.19 INPUT FUNCTIONS
This option allows the input 1 contact to be configured for different alarm
types.
Options: See following table
Default:
Input 1: Arm Zone 1
Input 2: Tamper (OR Arm Zone 2 [ZM2 only])
Input 3: Alarm Gate
Mode
Description
Arm Me
Arm the Energizer
Arm Zone 1
Arm Zone 1 of the Energizer
Arm Zone 2
Arm Zone 2 (ZM2 Only) of the Energizer
Arm Group
Arm the Energizers connected to the Keypad Bus
(Not Implemented)
Alarm Instant
Alarm triggers when contact changes
Alarm 3sec
Trigger an alarm state after 3 seconds
Alarm Gate 1
Gate 1 Alarm. Use the Gate Delay value to set a
timeout before the alarm
Alarm Gate 2
Gate 2 Alarm. Use the Gate Delay value to set a
timeout before the alarm
Alarm Exit/Entry
This is an Entry/Exit route contact. Configure the
Entry Delay and Exit Delay
Entry Route
This is an Entry route contact. Configure the Entry
Delay
Exit Route
This input does not affect the operation of the En
-
ergizer. Its value is sent via the Keypad bus
Pass Thru
This input does not affect the operation of the En
-
ergizer. Its value is sent via the Keypad bus
Tamper
This will trigger the Tamper Alarm immediately
Shutdown
This will trigger the Tamper Alarm immediately and
Disarm the Energizer. It will not allow the Energizer
to be Armed while in alarm state.