Page 26
Vir
tual K
eypad
© JVA Technologies. www.jva-fence.com
JVA JMB User Manual
8.4 CONTROL AND MONITOR PAGE
8 .4 .1 Arm and Disarm
The main page is the basic control hub with buttons to arm and disarm the
energizer.
8 .4 .2 Muting
The “Mute” button available on both zones (for a ZM2), or one zone (for
a ZM1 or ZM50) will mute any actively sounding alarms from a siren out
-
put that will have occurred on the fence. This does not clear any latched
alarms; this simply silences any siren that has been configured as an output
on that zone.
8 .4 .3 Clear
The “Clear” button is available on both zones (for a ZM2), or one zone (for a
ZM1 or ZM50) and it will clear any latched alarms but will not stop the siren
from sounding. To stop an output that has been configured as a siren, the
“Mute” button must be selected for that zone.