JVA JMB User Manual
11.4 BATTERY CHARGER FLOAT VOLTAGE
This option is used to set the battery charger float value, the correct setting
depends on the type of rechargeable 12V battery used.
Range 10.0V to 16.0V. Default 14.2V
Virtual Keypad:
Enter the
Configuration
page and adjust
Battery Float
ac
-
cordingly. Click
Save Settings.
11.5 BATTERY ALARM VOLTAGE
This option sets the battery voltage threshold below which the general
alarm will activate. This alarm can be set to activate one of the relays and
is part of the General alarm.
Note: The energizer will not turn off with this alarm, however if the battery
voltage continues to fall it will eventually switch off.
Range 0.0V to 16.0V. Default 10.0V
Virtual Keypad:
Enter the
Configuration
page and adjust
Battery Alarm
accordingly. Click
Save Settings.
11.6 RF REMOTE ID
This feature enables the energizer to be controlled via a JVA fence line,
radio frequency (RF), Remote Control*. If a fence line remote control is to
be used with this energizer, the option must be changed to match the ID of
that remote. Check the user manual of the remote control.
Default 0 (disabled).
Virtual Keypad:
Enter the
Configuration
page and alter the
RF Remote ID
value. Click
Save Settings.
*Compatible with one other manufacturer’s Remote Control.