Configur
ation O
ptions in Detail
Page 45
© JVA Technologies. www.jva-fence.com
11.16 DFD™
DFD™ enables the JMB to detect a fault at the end of very long fences.
Instead of only measuring the peak current the JMB with DFD™ calculates
the “real” current and rejects the “reactive” current.
The current displayed will usually be less than read by a standard hand-
held meter with this feature on. There is no theoretical limit to the length
of fence that the JMB can monitor with this feature on. Without DFD™ the
limit is approxi¬mately 10km.
Default OFF.
Virtual Keypad:
Enter the
Configuration
page and select or deselect Dis
-
tance Fault Detect accordingly. Click
Save Settings.
11.17 SECTORS
JMBx-ZM50 Only
This option allows your electric fence to be split up into sectors (sections
of fence). When a fault occurs (as defined by the total current exceeding
the “current alarm level”) the energizer will determine which sector the
short is in.
Each sector division needs to be programmed into the energizer. The sec
-
tor programming procedure is outlined in
Section 12 “Sector Programming
Method”
.
The energizer cannot show more than 1 faulted sector at any time
Range 0 to 50. Default 0
Virtual Keypad:
Enter the
Configuration
page and adjust
Sectors
accord
-
ingly. Click
Save Settings.
11.18 INPUT PROGRAMMING
All inputs can be set to any of the available functions (user assignable), all
input functions are selectable from a drop down list for each of three input
terminals.