Basic Device Configuration
29
Chapter 3: Configuring the Device
WebUI
1.
Configuration > Date/Time: Click the Sync Clock with Client button.
A pop-up message prompts you to specify if you have enabled the daylight
saving time option on your workstation clock.
2.
Click
Yes
to synchronize the device clock and adjust it according to daylight
saving time, or click
No
to synchronize the device clock without adjusting
for daylight saving time.
You can also use the
set clock
command in a Telnet or console session to manually
enter the date and time for the device.
Default Route
The default route is a static route used to direct packets addressed to networks that
are not explicitly listed in the routing table. If a packet arrives at the device with an
address for which the device does not have routing information, the device sends
the packet to the destination specified by the default route. To configure the default
route on the device:
WebUI
Network > Routing > Destination > New (trust-vr): Enter the following, then
click
OK
:
Network Address/Netmask: 0.0.0.0/0.0.0.0
Gateway: (select)
Interface: ethernet0/2 (select)
Gateway IP Address:
ip_addr
CLI
set route 0.0.0.0/0 interface ethernet0/2 gateway
ip_addr
save
Bridge Group Interfaces
The SSG 140 device is pre-configured with bridge group (bgroup) interfaces
identified as bgroup0/0 through bgroup0/2.
Bgroups let you group multiple Ethernet interfaces together. Each bgroup
constitutes its own broadcast domain and provides high-speed Ethernet switching
between interfaces within the group. You can assign a single IP address to each
bgroup interface. You can bind a bgroup interface to any zone.
You can unbind interfaces from a bridge group and assign them to a different
security zone. Interfaces must be in the Null security zone before they can be bound
to a bridge group. To bind a grouped interface to the Null security zone, use the
unset interface
interface
port
interface
command.
Содержание SSG140
Страница 20: ...SSG 140 Series Hardware Installation and Configuration Guide 20 Connecting the Device to a Network...
Страница 36: ...SSG 140 Series Hardware Installation and Configuration Guide 36 Resetting the Device to Factory Defaults...
Страница 58: ...SSG 140 Series Hardware Installation and Configuration Guide 58...