Known Problems and Limitations
53
Release 11.0.1
If you configured a static interface column and removed the major interface
These scenarios might occur if you administratively issue the
shutdown
and
no
shutdown
commands on the major interface in which the dynamic interface
column is configured.
Work-around
: Use the
no interface ip
ipAddress
command to remove the
dynamic subscriber interfaces. Although you can use the
dhcp delete-binding
command to remove the DHCP binding and the dynamic subscriber interfaces,
the DHCP client does not detect the binding removal and retains the lease.
System
You cannot use a configuration script to boot the E320 router. [Defect ID
80304]
If you hot swap an IOA and then remove it again before that IOA’s OK or FAIL
LED is illuminated, the associated line module can reset. [Defect ID
177313/177267]
Work-around
: Ensure that you firmly insert the IOA into the chassis when you
hot swap IOAs. Do not attempt a second hot swap of an IOA that has not
indicated that it completed the first hot swap cycle. You can remove the IOA
when either its OK or FAIL LED is illuminated.
If your router is in Manual Commit mode, then you must issue the
write
memory
command before you perform an SRP module switch or a manual
reload. You must do this even when you have made no changes to the system
configuration and the file systems are synchronized. [Defect ID 44469]
System Logging
The
show configuration category management syslog virtual-router default
command incorrectly displays logs for multiple syslog destinations when you
add a log to only one syslog destination. The
show log configuration
command shows the correct configuration. [Defect ID 84082]
TCP
The SRP module resets in any of the following circumstances on an E320 router
that has a line module configured with 5000 ANCP adjacencies: [Defect ID
176916]
When you issue the
issu initialization
command from the console and
then reload the line module from a Telnet session.
When the client that has the 5000 ANCP clients resets or an intermediate
switch resets.
When you reload the line module.