When ilmid uses a large amount of memory, the following error message displays:
“/kernel: Process (1702,ilmid) has exceeded 85% of RLIMIT_DATA: used 129084
KB Max 131072 KB.” [PR/495645: This issue has been resolved.]
■
The one-port OC12-3 PIC cannot support eight queues when the
no-concatenate
option is configured. [PR/499452: This issue has been resolved.]
■
When an F4 OAM is enabled for a VPI and the encaps for a unit are changed
using that VPI and VCI to ATM-CCC cell rrelay, followed by the deletion of the
logical interface, the VPI list might be corrupted . Any subsequent change can
cause the system to crash. [PR/499479: This issue has been resolved.]
■
On a 4–port ChOC3/STM1 and 12–port T1/E1 circuit emulation PICs, the ATM
logical interface packets counter does not increment if the PIC is configured in
the ATM IMA mode. [PR/500153: This issue has been resolved.]
■
When
t1-options
are configured at the
[edit interfaces ct1-x/y/z]
hierarchy level,
some ct1 interfaces of a 10xCHT1 IQ PIC might flap when the configuration
changes are committed. As a workaround, remove the
t1-options
. [PR/500820:
This issue has been resolved.]
■
Polling
ifInOctets
on Gigabit Ethernet IQ PIC VLANs might momentarily return a
higher value. [PR/500852: This issue has been resolved.]
■
On 40x1 Gigabit Ethernet PICs, very short fragments of fragmented TCP, UDP,
and ICMP packets may be incorrectly dropped with the diagnostic L4 length too
short. [501526: This issue has been resolved.]
■
The configured TTL set for GRE traffic is set properly for locally generated Routing
Engine packets, but is not set properly for transit packets. [PR/502087: This issue
has been resolved.]
■
In JUNOS Release 10.0, if the MX-MPCs power up while the A-DPCs are offline,
and if ISSU is performed, the MPCs will crash. [PR/502837: This issue has been
resolved.]
■
When an ATM AIS cell is received from the virtual channel under vlan-vci-ccc
encapsulation, the logical interface will be incorrectly marked down. There is no
workaround. [PR/503653: This issue has been resolved.]
■
The yellow marking for the three-color-policers is incorrect. Even after the excess
burst buffer is full, the yellow counters continue to increment at the same rate
as the green buffers. [PR/504192: This issue has been resolved.]
■
Under certain circumstances, the E3 IQ PIC might report bogus CCV, CES, and
CSES alarms. [PR/505921: This issue has been resolved.]
■
The
show interfaces diagnostics optics interface
command does not display the
unit of measurement when the received power is in a very low range (power <
5e-10). It shows the value of 0.00 without any unit of measurement. [PR/507653:
This issue has been resolved.]
■
On MX Series routers, the chassisd crashes when the SCB is taken offline and
removed. [PR/510950: This issue has been resolved.]