Forwarding and Sampling
■
The output firewall filter counter does not work when the firewall is configured
for discard next hop. [PR/404645: This issue has been resolved.]
■
Policers cannot be modified after a system upgrade due to a flaw in the parser
routine. This error occurs when the current item is deleted and the parser cannot
proceed to the next item. With the fix, the routine in the forwarding process
(dwfd) has been modified so that the next item in the object tree is fetched before
the current object is parsed. [PR/433418: This issue has been resolved.]
■
Under certain conditions for prefix optimization, the firewall compiler may
discard a prefix configured for accept. This issue depends on the set of prefixes
configured to match across the various terms. [PR/486633: This issue has been
resolved.]
■
When the MS PIC used for an RLSQ interface resides on an E3 FPC (M320), traffic
might stop flowing across the RLSQ interface after the policer on the interface
is deactivated. [PR/498069: This issue has been resolved.]
■
When a filter group is configured on an interface residing on an ES FPC, the
rpf-check configured on that interface will not function correctly. As a
workaround, deactivate the configured filter group. [PR/503609: This issue has
been resolved.]
■
After configuring a three-color-policer, a dfwc core file is generated. [PR/509742:
This issue has been resolved.]
High Availability
■
On an ISSU upgrade from JUNOS Release 9.3 to any of the current higher releases,
the ATM logical interfaces will flap. [PR/491511: This issue has been resolved.]
Interfaces and Chassis
■
When the ATM scheduler map is programmed, the code does not check if the
early packet discard (EPD) configured on the forwarding class exceeds the
max_epd that the hardware supports. [PR/70336: This issue has been resolved.]
■
The following messages are displayed on both the primary and secondary RLSQ
MS 500 PICs: “SCHED: %PFE-0: Thread 7 ran for x ms without yielding",
"Scheduler Oinker." [PR/286357: This issue has been resolved.]
■
On M Series and MX Series routers, the ifHCInOctets retrieved by SNMP may
report an incorrect value. [PR/420985: This issue has been resolved.]
■
The
show interfaces diagnostics optics
command displays wrong diagnostic
information for the SumitomoElectric SFP with vendor part number
SCP6F44-J3-ANE. [PR/463837: This issue has been resolved.]
■
For AnnexB, the
force
command may not work as expected when loss of signal
is present. This is because the previous command did not complete for both the
protect and the working circuit, and priority comparison does not consider the
signal fail condition. [PR/465906: This issue has been resolved.]
82
■
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
JUNOS 10.1 Software Release Notes