Class of Service
■
On an EX2200 switch, when a queue is oversubscribed and you modify a
scheduler with the
buffer-size exact
option on it such that it reduces the allocated
buffers on the queue, the queue can stop dequeueing packets. As a workaround,
stop traffic going out on the port, and deactivate and reactivate class of service
(CoS). You can also reboot the switch. [PR/481401: This issue has been resolved.]
Firewall Filters
■
The
accept
action and the
log
and
syslog
action modifiers in the firewall filter
configuration might not work as expected for packets destined for the switch.
[PR/406714: This issue has been resolved.]
■
If an ingress firewall has been configured with a LAG
interface
match condition
and you delete this firewall configuration, the forwarding (
pfem
) process might
create a core file. When the
pfem
process is restarted, it works as expected.
[PR/504273: This issue has been resolved.]
■
On EX3200 and EX4200 switches, if you configure an egress firewall filter with
the match condition
source-address
or
destination-address
on a VLAN and its
routed VLAN interface (RVI), the firewall filter might not work properly.
[PR/476626: This issue has been resolved.]
■
On an EX2200 switch when you add a
syslog
action modifier to the firewall filter,
the forwarding (
pfem
) process might create a core file when the filter binding is
changed from an egress VLAN to an ingress VLAN. [PR/495572: This issue has
been resolved.]
Hardware
■
On 48-port SFP line cards used in EX8200 switches, do not install a transceiver
in the first or last port on the bottom row (ports 1 and 47). Transceivers installed
in these ports are difficult to remove. As a workaround, remove the transceiver
by using a small flathead screwdriver or other tool to lift the lock on the
transceiver. [PR/423694: This issue has been resolved.]
Infrastructure
■
On an EX2200 switch, if the following message is displayed when the switch is
booting, the installed package might be corrupted:
mount_check: SHA1 (/packages/jkernel-ex-10.1-20090925.0) =
f45dd191b053b608dafecc0ef3ea329c9f85693b
!=5fe72546eed0c0cb83e6addc6709720f56e8b6da
As a workaround, reinstall the image from the loader prompt with the
-- format
option set. [PR/433663: This issue has been resolved.]
■
Though the
interface-range
configuration statement is not supported under the
[edit groups
] hierarchy, an error message might not be displayed when you use
the
interface-range
statement. [PR/453538: This issue has been resolved.]
Resolved Issues in JUNOS Release 10.1 for EX Series Switches
■
197
Resolved Issues in JUNOS Release 10.1 for EX Series Switches