Interfaces and Chassis
■
When forwarding-options is configured without route-accounting, commit goes
through with the message, "Could not retrieve the route-accounting." However,
no functionality is affected. [PR/312933: This issue has been resolved.]
■
The backup Routing Engine can fail to obtain mastership in the following cases:
■
re0 gets stuck and doesn't reboot.
■
Due to a hardware problem, re0 looses its connectivity with both the Control
Board and the Packet Forwarding Engine.
[PR/405412: This issue has been resolved.]
■
On MX Series routers, traffic is forwarded over the backup link even after the
primary link is disabled and enabled again. [PR/493861: This issue has been
resolved.]
■
When link trace entries are added in the path database, there is no check to
determine if the current number of entries have reached the path database size.
Because of this, the entries may grow to be greater than the path database size
(configured or default). [PR/494584: This issue has been resolved.]
■
Under certain circumstances a backup Routing Engine reboot followed by a
Routing Engine failover can cause the LACP to flap, which causes AE bundles to
flap. [PR/502937: This issue has been resolved.]
■
On MX Series routers with JUNOS Release 10.0R2 or higher, the backup Routing
Engine might report the following warning message upon commit once network
service is configured under the chassis stanza: "WARNING: network services flag
has been changed, please reboot system." [PR/505690: This issue has been
resolved.]
■
The Routing Engine on slot 1 takes mastership regardless of the user-configured
Routing Engine mastership priority. [PR/507724: This issue has been resolved.]
■
When the
show chassis hardware models
command or the
show chassis hardware
| display xml
command is used, the FRU part-number 710-013035 displays the
model number T1600-FPC3-ES instead of T640-FPC3-ES. [PR/514072: This issue
has been resolved.]
■
When the
show chassis hardware models
or
show chassis hardware | display xml
command is issued for M320-FPC*-E3 with part-numbers 710-025464,
710-025853, and 710-025855, the model number does not display correctly.
[PR/514074: This issue has been resolved.]
■
When traffic flows across IQE SDH/SONET interfaces, instantaneous inaccurate
traffic rate values with smaller packet sizes occur when the
show interface
command is issued. [PR/514330: This issue has been resolved.]
■
The output of the
show chassis hardware
command may not display the SIB
details when the SIB is inserted in the slot. [PR/515789: This issue has been
resolved.]
■
On some XENPAK modules, the output of the
show chassis hardware
command
shows the message "NON-JNPR UNKNOWN" when the FPC is booted. There is
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers
■
67
Issues in JUNOS Release 10.1 for M Series, MX Series, and T Series Routers