When a logical interface set has a shaping-rate less than the sum of the
transmit-rates of its queues and when the configuration is corrected so that the
logical interface set gets the right shaping-rate, ADPC might crash. [PR/523507]
Forwarding and Sampling
■
The numerical values configured for the ip-options match criteria on a firewall
filter matches any ip-options no matter what is specified. [PR/516778]
High Availability
■
The SSH keys are not in sync between the master and backup Routing Engine
when SSH is enabled after a graceful Routing Engine switchover (GRES).
[PR/455062]
■
When an ISSU upgrade is performed to or from JUNOS Releases 9.6R3 or 10.0R2,
the logical interface and logical interface sets that have traffic control profiles
configured on them will be affected. [PR/491834]
Interfaces and Chassis
■
For Automatic Protection Switching (APS) on SONET/SDH interfaces, there are
no operational mode commands that display the presence of APS mode
mismatches. An APS mode mismatch occurs when one side is configured to use
bidirectional mode, and the other side is configured to use unidirectional mode.
[PR/65800]
■
The output of the
show interfaces diagnostics optics
command includes the "Laser
rx power low alarm" field even if the transceiver is a type (such as XENPAK) that
does not support this alarm. [PR/103444]
■
On the M120 router, hot swapping the fan tray might cause the
Check CB
alarm
to activate. [PR/268735]
■
On the JCS1200 platform, when you issue the
clear -config -T switch[1]
command
using the management module, the switch module returns to its factory default
setting instead of the Juniper Networks default setting. As a workaround, do not
issue the command. [PR/274399]
■
On the Juniper Control System (JCS) platform, the control and management
traffic for all Routing Engines shares the same physical link on the same switch
module. In rare cases, the physical link might become oversubscribed, causing
the management connection to Protected System Domains (PSDs) to be dropped.
[PR/293126]
■
On a Protected System Domain (PSD) configured with a large number of BGP
peers and routes (for example, 5000 peers and 1,000,000 routes), FPCs might
restart during a graceful Routing Engine switchover (GRES). [PR/295464]
■
When two routers are connected via SONET/SDH interfaces that are configured
as container interfaces and the Routing Engine on one router reboots, the
container interfaces on the other router might go down and come up again.
[PR/302757]