The DHCP snooping database is not built after graceful Routing Engine switchover
(GRES) is performed twice. Even though packets are coming from the DHCP
server, they are not inserted in the DHCP relay. [PR/461318: This issue has been
resolved.]
■
If an interface is assigned to a VLAN before the interface's stg state is set, loops
might form in the network if a VLAN ID is assigned to the VLAN while the
interface is active in a redundant topology. [PR/472617: This issue has been
resolved.]
■
On EX2200 switches, the MIB OID
ipv6Forwarding
indicates that IPv6 is supported
even though IPv6 is not supported. The value of the
ipv6Forwarding.0
MIB object
is 1. [PR/473128: This issue has been resolved.]
■
On EX8200 switches, after a graceful Routing Engine switchover (GRES), you
can navigate through the Maintenance menu in the LCD even after the
Maintenance menu in the LCD has been disabled using the
set chassis lcd
maintenance-menu disable
command. As a workaround, delete the LCD
Maintenance menu configuration using the CLI on the new master switch, and
then disable the LCD Maintenance menu using the
set chassis lcd
maintenance-menu disable
command. [PR/473597: This issue has been resolved.]
■
In some rare cases, switch bootup fails when the JUNOS Software is loading. The
message
Device not ready
displays because the NAND flash is not responding.
Workaround: Power cycle the switch. [PR/482026: This issue has been resolved.]
■
If you attempt to set the time zone to
Europe/Berlin
on a switch with dual Routing
Engines, the
commit
command might fail. [PR/483273: This issue has been
resolved.]
■
The name of the
ethernet-switching-options authentication-whitelist
statement will
be changed. The new name is correct in the documentation but is shown in the
CLI as
ethernet-switching-options white-list
. [PR/487167: This issue has been
resolved.]
■
A memory leak might be present in the
pfem
SPF database. As a workaround,
you can restart the forwarding (
pfem
) process. [PR/493197: This issue has been
resolved.]
J-Web Interface
■
In the J-Web interface, uploading a software package to the switch might not
work properly if you are using Internet Explorer version 7. [PR/424859: This
issue has been resolved.]
■
In the J-Web interface, the Edit MSTI window in the Spanning Tree Configuration
page might not display details of an uncommitted interface configuration.
[PR/433506: This issue has been resolved.]
■
In the J-Web interface, the menu on the left side of the J-Web pages and contents
of the J-Web pages might disappear when you double-click the Troubleshoot tab.
As a workaround, click the Dashboard tab or the Configure tab, and then click
the Troubleshoot tab to display the menu and contents of the page. [PR/459936:
This issue has been resolved]