– 83 –
No.
Description of error detected
Cause of occurrence expected
Items to be checked
E811
Overvoltage
• When voltage higher than guaranteed
• Check whether the applied power voltage
one is inputted.
is higher than the rated v (plus) 10%
or more.
• When the 100V input power is applied
• Check whether 100V/200V changeover
int the state of 200V setting.
connector is improperly set.
• JUS : 220V is applied to the box of 120V.
In the aforementioned cases, POWER
• CE : 400V is applied to the box of 230V.
p.c.b is broken.
E813
Low voltage
• When voltage lower than guaranteed
• Check whether the voltage is lower than
one is inputted.
the rated voltage - (minus) 10% or less.
• When the 100V input power is applied
• Check whether 100V/200V changeover
int the state of 200V setting.
connector is improperly set.
• JUS : 120V is applied to the box of 220V.
• Inner circuit is broken by the applied
• Check whether fuse or regenerative
overvoltage
resistance is broken.
E906
Communication trouble between
• Operation panel cord is disconnected.
• Check whether operation panel connectors
operation panels
• Operation panel is broken.
(CN34 and CN35) are loosened or
disconnected.
• Check whether operation panel cord is
disconnected since the cord is caught
with machine head.
E924
Motor driver failure
• Motor driver has broken.
E944
Left needle control impossible
• Left needle has shifted from the origin
• Check whether the left needle origin
(When LH-4168, or 4188 is selected)
during holding it.
sensor is broken.
• Left needle has shifted from the origin
• Check whether needle bar has shifted
during releasing left needle.
from the holding position by the exterior
force.
• Check whether the needle control con-
nectors (CN55 and CN56) have come
loose or are dislodged.
• Check whether the present program is
arranged for the simultaneous driving of
multiple solenoids with the step pattern
of IP-110.
E945
Right needle control impossible
• Right needle has shifted from the origin
• Check whether the right needle origin
(When LH-4168, or 4188 is selected)
during holding it.
sensor is broken.
• Right needle has shifted from the origin
• Check whether needle bar has shifted
during releasing left needle.
from the holding position by the exterior
force.
• Check whether the needle control con-
nectors (CN55 and CN56) have come
loose or are dislodged.
• Check whether the present program is
arranged for the simultaneous driving of
multiple solenoids with the step pattern
of IP-110.