![JUKI SC-910N Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/juki/sc-910n/sc-910n_engineers-manual_2029524030.webp)
– 26 –
2)
Error code list (Error display in panel)
There are the following error codes in this device.
These error codes interlock (or limit function) and inform the
problem so that the problem is not enlarged when any problem is discovered. When you request our service, please
confirm the error codes.
—
UP position detection error when turn-
1. When needle position is not UP position at the
1. Set to UP position by turning handwheel by hand.
ing ON the power
time of turning ON the power.
2. Connect synchronizer connector.
—
Media cover open
1. Lid of media slot is open.
Close the lid.
E000
Execution of data initialization
1. EEPROM initialization is executed.
—
(Not error)
2. Resistor pack is replaced.
3. When machine head is replaced.
E003
Disconnection of synchronizer connector
1. When position detection signal is not inputted from
1. Check the synchronizer connector (CN30) for loose connection and disconnection.
the sewing machine head synchronizer.
2. Check whether the synchronizer cord has broken since the cord is caught in the
2. When the synchronizer has broken.
machine head or the like.
E005
Synchronizer upper position sensor failure
E007
Overload of motor
1. When the machine head is locked.
1. Check whether the thread has been entangled in the motor pulley.
2. When sewing extra-heavy material beyond the
2. Check the motor output connector (4P) for loose connection and disconnection.
guarantee of the machine head.
3. Check whether there is any draw when turning motor by hand.
3. When the motor does not run.
4. Motor or driver is broken.
E008
Machine head connector failure
When the machine head connector is not properly read.
Check the machine head connector (CN31) for loose connection and disconnection.
(Resistance pack)
E011
Compact flash (TM) not inserted
Compact flash (TM) is not inserted.
Return after reset operation.
E012
Read error
Data read from compact flash (TM) is not possible.
Return after reset operation.
E013
Write error
Data write to compact flash (TM) is not possible.
Return after reset operation.
E014
Write protect
Compact flash (TM) is in write prohibition state.
Return after reset operation.
E015
Format error
Formatting cannot be performed.
Return after reset operation.
E016
External media capacity over
Media capacity of compact flash (TM) is short.
Return after reset operation.
E019
File size over
File is too big.
Return after reset operation.
E021
Access error
Abnormality of access of file
Return after reset operation.
E032
File compatibility error
There is not file compatibility.
Turn OFF the power.
E046
Both-needle lock
When the power supply is turned on, both needles are
1. Check whether the right or left needle position origin sensor is broken.
(When LH-4168, 4188 is selected)
locked. (Needles are located in rising positions.)
2. Check whether the sensor connector wire is broken or disconnected.
E053
Execution of panel backup data
When model code of panel does not agree with that
Turn OFF the power.
initialization. (Not error)
of control box.
When executing initialization operation when the panel.
E220
Grease fill-up time information
When grease fill-up time to the specified place has
After turning OFF the power, perform grease fill-up, and set Function No. 118 to “1”.
come.
When grease fill-up cannot be performed during sewing, release of error can be
performed with the reset key of the panel.
E221
Grease-up error
LH-41** Machine head greasing alarm
Replenish the specified grease and execute resetting operation.
(Grease replenishment alarm after the lapse of specified time)
No.
Description of error detected
Cause
Item to be checked or corrective measure
E004
Synchronizer upper position sensor failure
Содержание SC-910N
Страница 1: ...40063908 No E381 00 ENGINEER S MANUAL SC 910N...
Страница 88: ...84 MEMO...