– 51 –
(1) How to set the counter
①
Selecting the counter setting
<Mode screen>
②
Setting the type of counter, current value of counter and preset value for counter
<Counter type selection screen>
Type of counter
Current value of
counter
Preset value for counter
Press
❺
on the mode screen. Select "02
Counter setting". Press
❼
to display the
counter setting screen.
1. The type of counter can be selected by pressing
❻
.
2. Select the target item by pressing
❺
.
The value of the item you have selected can be
changed by pressing
❻
.
If
❷
is pressed while the current value
or set value of the sewing counter is selected,
the current value or set value can be reset to "0"
(zero).
3. When
❽
is pressed, the screen returns
to the mode screen. When
❽
is pressed
again, the screen returns to the sewing screen.
Type of counter
Setting item
Setting range
Sewing counter
(Count-up counter) (Count-down counter)
Current value
0 to 9999
Set value
0 to 9999
Pitch time counter
Pitch time
1.0 to 999.9
(Unit: Second)
Counter unused
(No setting item)
❺
❺
❼
❷
❻
❽