– 65 –
Error code
Description of error
Cause
Item to be checked
E000
Execution of data initial-
ization (This is not an
error.)
• In the case the control box is
changed.
• In the case the initialization
operation is executed.
Not a failure
E007
Motor overload
• In the case the machine head is
locked.
• In the case of sewing ex-
tra-heavy weight material that
exceeds the guaranteed mate-
rial thickness.
• In the case the motor fails to
rotate.
• In the case of the motor or driver
failure.
• Check whether the pulley is entangled with
thread.
• Check whether the motor output connector
has loosened.
• Check whether the motor can be turned
smoothly by hand.
E011
Media is not inserted
• In the case no media is inserted. • Turn the power OFF and check for a media.
E012
Read error
• In the case data stored on the
media cannot be read.
• Turn the power OFF and check for a media.
E013
Write error
• In the case data cannot be writ-
ten on the media.
• Turn the power OFF and check for a media.
E014
Write protect
• In the case the media is placed
in the write-prohibition state.
• Turn the power OFF and check for a media.
E015
Format error
• In the case formatting of the
media cannot be carried out.
• Turn the power OFF and check for a media.
E016
External media over-ca-
pacity
• In the case the capacity of media
is not enough.
• Turn the power OFF and check for a media.
E019
File size over
• In the case of attempting to read
the file that exceeds the maxi
-
mum possible size from the USB
thumb drive to the operation
panel.
• Turn the power OFF and check the USB
thumb drive.
E022
File undetected
• In the case of attempting to read
the file that is not stored in the
USB thumb drive to the opera-
tion panel.
E031
Air pressure drop
• In the case the air pressure has
dropped.
E032
File compatibility error
• In the case the file is not com
-
patible.
• Turn the power OFF and check for a media.
E071
Motor output connector
disconnection
• The motor connector has slipped
off.
• Check for looseness and slip-off of the motor
output connector.
E079
Overload operation error • An excessive load is applied to
the main shaft motor.
E081
Cloth puller motor devia-
tion error
• Load applied to the cloth puller
motor is too large for the motor
to operate.
• Check whether the cloth puller motor runs
smoothly.
E204
USB thumb drive insertion • This error message is displayed
in the case the sewing machine
is started while a USB thumb
drive remains in the sewing
machine.
• Remove the USB thumb drive.
4-7. List of errors
Содержание MS-1261A-DWS
Страница 1: ...MS 1261A DWS INSTRUCTION MANUAL...