![JUKI MS-1261A-DWS Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/juki/ms-1261a-dws/ms-1261a-dws_instruction-manual_2029478050.webp)
– 47 –
(2)
List of memory switch data
No
Item
Setting range
U001
Soft start function
0 to 9 stitches
0: No soft start
1 - 9: Number of stitches to be sewn at the soft-start sewing
speed
U014
Sewing count function
1 to 3
1: Counter counts one when the back part of the pedal is de-
pressed to the second level.
2: Sewing counter switch input
3: Counter counts one every time the absence of material is
detected after the sewing machine has performed sewing
in the state the material is present.
U021
Presser foot goes up
when the pedal is at its
neutral position
0 to 1
U035
Lowest sewing speed by
pedal
150 to 600 sti/min
U037
Sewing speed for soft-
start function
100 to 5500 sti/min This memory switch data item is used for setting the sewing
speed to be employed while the soft-start function works.
U038
One-shot sewing speed
100 to 5500 sti/min This memory switch data item is used for setting the sewing
speed to be employed while the one-shot sewing function
works.
U039
Rotation starting position
10 to 1000
This memory switch data item is used for setting the position
from which the sewing machine starts operating by depress-
ing the pedal. (Pedal stroke)
U040
Acceleration starting
position
10 to 1000
This memory switch data item is used for setting the acceler-
ation starting position of the pedal with reference to its neutral
position. (Pedal stroke)
U041
Presser-foot lifting start-
ing position
–500 to –10
This memory switch data item is used for setting the upper
position of the presser foot by operating the pedal. (Pedal
stroke)
U042
Presser-foot lowering
starting position
10 to 500
This memory switch data item is used for setting the position
of the pedal at which the presser foot starts coming down with
reference to its neutral position.
U043
Cloth-puller lifting and
chain-off thread-cutter
operation starting posi-
tion
–1000 to –100
This memory switch data item is used for setting the position
of the pedal at which the cloth puller goes up (in the case the
pedal position at which the cloth puller goes up is set so that
it goes up after the presser foot with U206), and for setting
the position of the pedal at which the chain-off thread cutter
operates (in the case the operation of chain-off thread cutter
by depressing the back part of pedal is enabled with S043),
with reference to its neutral position. (Pedal stroke)
U044
Maximum sewing speed
position
10 to 15000
This memory switch data item is used for setting the position
of the pedal at which the sewing machine reaches its max-
imum sewing speed with reference to its neutral position.
(Pedal stroke)
U045
Pedal neutral position
correction value
–150 to 150
This memory switch data item is used for setting the neutral
position of the pedal.
U047
Presser-foot lifting end
position
–1000 to –100
This memory switch data item is used for setting the position
reached by depressing the back part of pedal to the first level
(first-level spring position)
U049
Presser-foot lowering
time
0 to 500 ms
This memory switch data item is used for setting the time
during which the presser foot comes down.
U055
Presser-foot lifting after
depressing the back part
of pedal to the 2nd level
0 to 1
This memory switch data item is used for setting the function
for keeping the presser foot at its upper position when the
back part of pedal is depressed to the 2nd level after the com-
pletion of sewing.
0: Disabled 1: Enabled
Содержание MS-1261A-DWS