– 101 –
Error
code
Description of error
Cause
Item to be checked
E967 Deviation error of the al-
ternating vertical move-
ment motor
• The alternating vertical movement motor
is overloaded.
• Does the alternating vertical move-
ment motor move smoothly without
hitch?
E971 Pitch motor IPM over-
current protection
• Pitch motor maloperation.
E972 Pitch motor overload
• In the case the pitch motor is applied
with an excessive load.
• Check whether the pitch motor runs
smoothly.
E975 Presser motor IPM
over-current protection
• Presser motor maloperation.
E976 Presser motor overload
• In the case the presser motor is applied
with an excessive load.
• Check whether the presser motor
runs smoothly.
E977 CPU fault
• In the case of a program fault.
E978 Network communication
fault
• In the case the data received from the
network is damaged.
E979 IPM overcurrent protec-
tion
• Alternating vertical movement amount
motor operation failure
E980 Alternating vertical
movement amount mo-
tor overload
• The alternating vertical movement
amount motor is overloaded.
• Does the alternating vertical move-
ment amount motor move smoothly
without hitch?
E985 Pitch motor return-to-or-
igin error
• In the case the pitch motor has failed to
return to its origin.
• Check whether the origin of the pitch
motor has been adjusted properly.
E986 Alternating vertical
movement amount mo-
tor origin return-to-origin
error
• In the case the alternating vertical
movement amount motor has failed to
travel to its origin.
• Is the origin of the alternating vertical
movement amount motor adjusted
incorrectly?
E987 Suspended ruler re-
turn-to-origin error
• In the case the suspended ruler motor
has failed to travel to its origin.
• Is the origin sensor (CN97) of the
suspended ruler is properly connect-
ed?
E999 Main software rewriting
• In the case of rewriting the main soft-
ware.
• It is not an error.
Содержание LU-2860V-7
Страница 1: ...LU 2860V 7 INSTRUCTION MANUAL ...