![JUKI LU-2860V-7 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/juki/lu-2860v-7/lu-2860v-7_instruction-manual_2029958103.webp)
– 98 –
6-6. List of errors
Error
code
Description of error
Cause
Item to be checked
E000 Execution of data initial-
ization (This is not an
error.)
• The existing control box has been re-
moved and a new one is mounted.
• In the case the initialization operation is
executed.
This is not a failure.
E007 Motor overload
• In the case the machine head is locked.
• In the case of sewing extra-heavy
weight material that exceeds the guar-
anteed material thickness.
• In the case the motor fails to rotate.
• In the case of the motor or driver failure.
• Check whether the pulley is entan-
gled with thread.
• Check whether the motor output
connector (4P) has loosened.
• Check whether the motor can be
turned smoothly by hand.
E009 Overtime of solenoid
energization
• In the case the length of solenoid ener-
gizing time has exceeded the assumed
one.
E011 Media is not inserted
• In the case no media is inserted.
• Turn the power OFF and check for a
media.
E012 Read error
• In the case data stored on the media
cannot be read.
• Turn the power OFF and check for a
media.
E013 Write error
• In the case data cannot be written on
the media.
• Turn the power OFF and check for a
media.
E014 Write protect
• In the case the media is placed in the
write-prohibition state.
• Turn the power OFF and check for a
media.
E015 Format error
• In the case formatting of the media can-
not be carried out.
• Turn the power OFF and check for a
media.
E016 External media over-ca-
pacity
• In the case the capacity of media is not
enough.
• Turn the power OFF and check for a
media.
E019 File size over
• In the case of attempting to read the
custom pitch data or condensation cus-
tom data which exceeds the maximum
permissible data size into the memory
of sewing machine from the USB thumb
drive.
• Turn the power OFF and check the
USB thumb drive.
E022 File undetected
• In the case of attempting to read a file
which is not stored in the USB thumb
drive into the operation panel.
E032 File compatibility error
• In the case the file is not compatible.
• Turn the power OFF and check for a
media.
E071 Slip-off of the motor
connector
• In the case the motor connector has
slipped off.
• Check for looseness and slip-off of
the motor output connector.
E072 Motor overload when the
thread trimmer operates
• Same as E007.
• Same as E007.
E079 Overload operation error • Load applied to the main shaft motor is
excessively large.
E081 Feed driving motor lock
• In the case the feed driving motor is
locked.
• Check whether the feed driving motor
operates smoothly.
E204 USB insertion
• In the case the sewing machine is start-
ed up without removing the USB thumb
drive.
• Remove the USB thumb drive.
Содержание LU-2860V-7