– 95 –
No.
Item
Setting range
Unit
U068
Presser foot lifting operation changeover
The presser foot lifting operation when depressing the back part of pedal is
changed over.
0: 2-step operation / 1: Manual operation depending on the pedal stroke when the
back part of pedal is depressed
0 to 1
-
U087
Pedal acceleration characteristic
0: Standard / -1 to -10: Low-frequency low acceleration / 1 to 10: Low-frequency
high acceleration
-10 to 10
ー
U089
Needle bar stop position when the power is turned ON
0: Upper stop position/ 1: Reverse-rotation needle up position
0 to 1
ー
U090
Initial-start upper-position stopping function
0: The sewing machine stops with its needle up after checking the panel.
1: The machine automatically stops with its needle up.
0 to 1
ー
U092
Speed reducing function for reverse feed stitching at beginning of sewing
Speed reduction function after the completion of start reverse feed stitching is set.
0: Speed is not reduced. / 1: Speed is reduced
0 to 1
ー
U093
Needle up/down correction switch adding function
Needle up/down correction switch operation after the power-ON or after thread
trimming is set.
0: Normal / 1: One-stitch correction after thread trimming / 2: Needle entry align-
ment function after thread trimming
3: In addition to the operation 2, the needle entry alignment is performed by low-
ering the presser foot and the needle lifting function works by operating the thread
trimmer
0 to 3
ー
U096
Maximum sewing speed
The initial value differs with the machine head.
150 to 3500
sti/min
U120
Main shaft reference angle correction
The main shaft reference signal angle (0 degree) is corrected with the value set
using this memory switch.
-60 to 60
Degree
U121
Upper position angle correction
The position at which the sewing machine stops with its needle up is corrected.
-15 to 15
Degree
U122
Lower position angle correction
The position at which the sewing machine stops with its needle down is corrected.
-15 to 15
Degree
U164
Pedal input high-speed switch function
0: Normal pedal / 1: To be used as the high-speed switch
0 to 1
ー
U173
Thread clamp ON retaining time
Period of time to retain the thread clamp in the ON state.
1 to 60
S
U179
Needle bar home position retaining limit time
Retaining time for the control to keep the needle bar at its home position (0: No
limit)
0 to 10
m
U182
Sewing counter stopping function
0: The sewing machine does not stop even when the sewing counter completes
counting.
1: When the counter completes counting, the sewing machine start after thread
trimming is prohibited.
* Note that the prohibition function is disabled in the case the initial value of
counter is 0 (zero).
0 to 1
ー
U183
Number of times of thread trimming for sewing counter
1 to 20
ー
U194
Thread tension changeover setting when lifting the presser foot
0: OFF / 1: Normally ON / 2: Only after thread trimming / 3: Only during the imme-
diate stop
0 to 3
ー
U195
Thread tension when lifting the presser foot (right)
0 to 200
ー
Содержание LU-2860V-7