– 129 –
3
1
4
2
[When using CP-20]
* Perform grease supplement when the errors below are displayed or once a year (either one
which is earlier). After performing grease supplement, call memory switch No. 245 and set the
value to "0" with the reset key.
When the sewing machine has been used for a certain number of times of sewing, error code No. E220
is displayed on the operation panel at the time of turning ON the power. This display informs the opera-
tor of the time of replenishing the designated places with grease. Be sure to replenish the places with
the grease below. Then call the memory switch No. 245 and set it to "0" with the RESET key.
Even after the display of the error No. E220, when the RESET key is pressed, the error is released, and
the sewing machine can be continuously used. Afterwards, however, the error No. E220 is displayed ev-
ery time the power is turned ON.
In addition, when the sewing machine is used further for a certain period of time without replenishing the
designated places with grease after display of error No. E220, error No. E221 is displayed and the sew-
ing machine fails to operate since the error cannot be released even when the RESET key is pressed.
When the error No. E221 is displayed, be sure to replenish the designated places below with grease.
Then start up the memory switch and set No. 245 to "0" with the RESET key.
(1) Replenishing the eccentric cam section with grease
1) Open the upside cover
1
and remove the
grease
2
.
2) Remove rubber cap
4
located on the side of
eccentric cam
3
. Then replenish there with
grease.
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of the
sewing machine.
Use grease tube (Part No. 40013640) supplied as accessories to replenish the designated
places below with grease.If grease other than the designated one is replenished, damage
of components will be caused.
After replenishing the places with grease, the error No. E220 or No. E221 is displayed
again unless the memory switch No. 245 is changed to "0".