Fault
6
Fault
Opening of devices and replacement of parts subject to water pressure must only be
performed by licensed persons to ensure device safety and leak-tightness.
Deleting the fault indication:
– Press <OK> key.
or
– Pull the power supply unit out of the
socket and plug back in after about 5 s.
7
Servicing
7.1
Cleaning
Only use clear drinking water to clean the
housing.
Standard all purpose cleaners and glass
cleaners can contain up to 25 % solvent or
alcohol (methylated spirits).
These substances can chemically attack the
plastic parts resulting in embrittlement and
even breakage.
Therefore do not use these types of
cleaners!
Indication on the
Cause
Remedy
Attention! Fault
Reg. Drive
Regeneration drive
defective.
Notify customer service! Unplug the power
supply unit! If fitted, switch the bypass
valve to bypass!
Attention! Fault
Salification
Salting process de-
fective, container
overfilled or leak.
Check the brine level in the salt reservoir!
Reset fault indication! If the fault occurs
again, notify customer service!
Attention! Fault
Filling time
Replenishment
timeout.
Water supply may be interrupted. If the
cause cannot be found, notify customer
service.
When communicating with customer
service, please always have the de-
vice number and order number avail-
able (see fig. 12).