10
JUDO i-soft@home
Installation
4.1.1 Requirements for the place of
installation
– The ambient temperature must not ex-
ceed 30 °C!
– So that it is possible to safely drain the
waste water (regeneration) during oper-
ation and also in the event that a system
defect occurs, the specifications given in
chapter 4 “Installation” must be precisely
followed!
If the waste water cannot be safely and
completely drained, it is possible that
property damage to the home and fur-
nishings may be caused by the water.
– A shut-off valve must be installed up-
stream of the water softening system if
no bypass valve (JQX) is fitted. This al-
lows the water supply to be disconnect-
ed for water softening unit maintenance,
repairs or in case of malfunction.
– The installation room must be dry and
free from frost. Unauthorised persons
must not be able to access the water sof-
tening system.
– The water softening system must not be
subject to severe impacts.
– The device can be installed in all com-
mercially available drinking water pipes.
– Installation of the water softening unit
up-
stream of the
water meter is forbidden!
4.1.2 Mounting orientation
4.1.3 Power supply
The mains voltage must not be interrupt-
ed (e.g. via a light switch).
If the water softening system does not have
a permanent power connection,
– Regeneration will not take place,
– No fault warnings will be output.
– Water leakage or even water damage
may occur during a regeneration as a re-
sult of a loss of power.
4.2
Installation of the rotary flange
fitting (JQE)
The rotary flange fitting serves as a connect-
ing piece between the pipe and the water
softening unit.
It is suitable both for horizontal and vertical
pipes.
The installation height depends on the pipe
course. The minimum installation height
measured from the ground to the middle of
the pipe is 52 cm.
The rotary flange fitting must be installed
in the direction of flow. This is indicated
by an arrow integral with the casting (see
fig. 3)
.
To ensure fault-free operation, ob-
serve the following requirements:
A permanent power connection
(230 V, 50 Hz) must be available.
Always install the water softening
system in an upright position
(± 5°)! If this is not observed, in-
correct functioning may result.
A splash-proof socket, complying
with the legal regulations for wet are-
as, is required for the power supply
unit.
Fig. 3:
Rotary flange fitting
If this requirement is ignored, the
water softening unit will not work.