![Jøtul GI 545 DV MV Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/jotul/gi-545-dv-mv/gi-545-dv-mv_installation-and-operation-instructions-manual_2037734028.webp)
28
139919_GI 545 DV and DV MV 5/19
8.2 Blower Operation
(if equipped)
Figure 8.5. Blower controls.
Follow these operating instructions if the fireplace is
equipped with a blower.
MANUAL OPERATION:
In the Manual switch position, the blower will power
on regardless of firebox temperature. Blower speed
is controlled by the adjustment knob on the switch
panel. Under Manual operation, the blower will remain
ON regardless of burner operation until switched to
AUTO or OFF.
AUTOMATIC OPERATION:
The blower will power ON when its thermostat
(snapstat) reaches 140°F (60°C). When the burner is
shut off, the blower will continue to operate until the
firebox temperature cools below 140°F.
8.3 Thermostatic or Remote Control
See the accessory manufacturer’s operation instructions.
1. Set the fireplace burner mode switch to the STAT
position for remote control.
2. Light the pilot following the instructions found in this
manual and on the appliance rating plate. When the
pilot is lit, the burner will respond to calls for heat
either thermostatically or by remote transmitter.
GI 545 DV MV PILOT LIMIT NOTE:
The pilot will automatically extinguish after 7 days if
there is no call for heat during that period. The pilot
light will then need to be relit following the lighting
instructions in this manual or on the rating plate.
With proper care and maintenance, your appliance will
provide you with years of enjoyment. If you experience
any problem with your fireplace insert, contact your Jøtul
Authorized Dealer for assistance.
KEEP THIS MANUAL FOR REFERENCE AND MAKE IT
AVAILABLE TO ANYONE USING OR SERVICING THE INSERT.
This appliance and venting system should be
inspected before use and at least annually by a qualified
service technician
9.1 General Cleaning
• Vacuum the controls area under the firebox at
least monthly or more frequently if pet hair is in
the environment. Always keep the appliance area
clear and free from combustible materials, gasoline
and other flammable liquids. ALWAYS BE SURE THE
BURNER AND FIREBOX ARE COLD before using a
vacuum cleaner.
• The firebox should be vacuumed at least annually
and more frequently if pets are in the house. Use
a flexible attachment to reach into the valve
compartment and blower area.
• Use a soft brush attachment to vacuum the log set.
• Inspect the pilot assembly for corrosion and have any
damaged components replaced by a qualified service
technician. Remove any debris from burner ports,
particularly the pilot carry-over ports. See
fig. 7.20,
page 21.
9.2 Gasket Inspection
• Inspect the glass gasket annually. Examine the
gasket for signs of deterioration or stiffness and
confirm that the gasket maintains a positive seal.
This is important to prevent combustion gases
escaping into the room. Replace the gasket if
necessary. Refer to the replacement parts list on
pages 31.
9.0 Maintenance
CAUTION:
ALWAYS DISCONNECT ELECTRICAL POWER WHEN
SERVICING THIS APPLIANCE.
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING THE CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. ALWAYS VERIFY PROPER OPERATION
AFTER SERVICING THE APPLIANCE.
Содержание GI 545 DV MV