13
139262 Rev_H
9 / 11 / 2012
4.6
Jøtul F
50
TL Clearance Specifications
UNPROTECTED WALLS
PROTECTED WALLS
PER NFPA211 OR CAN/CSA -B365-M93
SIDE
REAR
CORNER
SIDE
REAR
CORNER
Single Wall Connector
A
14” / 356 mm
B
18” / 457 mm
C
12” / 305 mm
D
12” / 305 mm
E
8” / 203 mm
F
8.5” / 216 mm
Single Wall Connector
w/ Flue Collar Heat Shield
G
16” / 406 mm
H
10” / 254 mm
I
11” / 280 mm
J
8” / 203 mm
K
5” / 127 mm
L
6” / 153 mm
Double Wall Connector
M
14” / 356 mm
N
9” / 229 mm
O
12” / 305 mm
P
6” / 152 mm
Q
8” / 203 mm
R
6” / 152 mm
Double Wall Connector
w/ Flue Collar Heat Shield
S
14” / 356 mm
T
6” / 152 mm
U
12” / 305 mm
V
5” / 127 mm
W
6” / 152 mm
X
3.5” / 89 mm
Alcove w/ Double-Wall
Connector
A
16” / 406 mm
B
19” / 483 mm
N/A
D
6” / 152 mm
E
8” / 203 mm
N/A
Figure 16. Clearance Diagrams. All specifications applicable to both top and rear exit configurations.