Fig. 53: Clean the outside of the device
with a damp microfiber cloth.
If the casing is in stainless steel, use
specific products for this material.
Fig. 52: Replace the external cover by
fixing it to the pins.
The ionizing tube is the component of the device that has deteriorated over time to the point where
it needs to be replaced. Components must be replaced when signs of wear appear, indicated
by oxide on the internal mesh of the condenser, which will make it turn white, and by the glass
looking dull.
The
JO
NIX
up in
device signals the need to replace the ionizing tube every 14000 hours of
operation (factory setting) through the alarm led (red led) on.
The parameter 14000 hours of operation can be changed via the optional EVO display (see
chapter 9 "Optional EVO DISPLAY").
10.2.2 Ionizing tube replacement
Pay particular attention to the air passage grid: check that they are not dirty to
ensure air passage.
10.2.3 External cleaning of the device
Do not use liquid detergents,
sprays, soaps or other
products directly on the
device.
ATTENTION: The perforated
ambient air inlet grid must be
positioned at the filter.