Place the toothed washers, washers,
and grounding wires in turn, and screw the
screws into the grounding holes to connect
the two adjacent components.
5.6 Electrical Installation
All wiring should b e p e r f o r m e d b y
a qualified and trained person in accordance
with local regulations and procedures.
Modules could be connected in series
t o i n c r e a s e t h e o p e r a t i n g v o l t a g e b y
inserting the positive plug of one module
into the negative plug of another module.
Always ensure that the contact points
are corrosion-resistant , clean, and dr y
before wiring modules. If the polarities
of modules connected wrong, may lead
to irreparable damage. Before modules
connected in parallel, please check the
v o l t a g e a n d p o l a r i t y o f e a c h m o d u l e
array. If the polarity of products is opposite
or Voltage difference greater than 10V
founded after measurement, please check
the configuration of module array before
its access to power grids.
All cables and connectors u s e d t o
connect the DC system must have similar
(or higher) le vel . I t i s s u g g e s t e d t h a t
a l l c a b l e s s h o u l d r u n i n p r o p e r c a b l e
ducts and should be located away from
the water-prone area. Each module has
two standard 90°C shading output cables
with a plug-and-play connector on each
terminal. Jolywood modules are equipped
w i t h a D C co p p e r c a b l e w i t h a c r o s s -
sectional area of 4mm2, system voltage
1500V DC, insulation layer maximum work
temperature up to 90°C, also UV-resistant.
All cables used to connect the DC system
m u s t h a v e s i m i l a r o r h i g h l e v e l . I t i s
required that all wiring and electrical
connections should be comply with the
appropriate National Electrical Code.
12
Jolywood (Taizhou) Solar Technology Co.,Ltd.
Kaiyang Rd., Jiangyan Economic Development zone, Taizhou City, Jiangsu Province, P. R. China
www.jolywood.cn
+86-523-8061 2361
M o d u l e co u l d b e g r o u n d e d w i t h a
grounding equipment listed by a third party.
The equipment must be installed in accordance with
the instructions given by the grounded equipment
manufacturer.
Please visit http://www.jolywood.cn/ to
view the “Product Catalog” link for detailed
grounding holes locations and dimensions.
. The electrical contact is formed by
penetrating the anodized coating of the
aluminum frame and tightening the ground
screw (together with the star washer) to
a n a p p r o p r i a t e t o r q u e o f 2 5 l b f. i n . A
properly sized ground wire (solid bare
copper wire according to American Wire
Gauge 6 to 12) should be selected and
mounted under the connecting bolt.
wire could be made with copper, copper
alloy or other material, which should also
be in accordance with the requirements
of corresponding National Electrical Code.
The grounding conductor must be connected
to the ground through a suitable grounding
methods.
Installation Manual
- Jolywood N-type Mono-crystalline Double Glass Module