① M8 screw ② Flat washer ③ Spring washer
④ Nut ⑤ Mounting rail
Note: The above standard installation is used
in the Jolywood standard Clamp. For details,
please refer to the Jolywood standard clamp
drawing.
Bolt mounting method:
5.4
Framed Bifacial Double-Glass modules
(installation with bolts)
a) The modules should be bolted to the
support structure using the mounting holes on
the back of the frame.
b) Each modules needs to be fastened by
at least 4 points on two opposite sides.
c) M8 x 1.25 (5/16”) bolts and nuts should
be used. The yield strength of bolts and nuts
should not be less than 450 MPa, and the reco-
mmended torque is 16-20 Newton meters.
d) The outer flat washer needs to use M8
(A2-70), a stainless steel (SUS304) flat washer
with an outer diameter of 20±2 mm and a
thickness of 1.1-1.2 mm; the corresponding
stainless steel spring washer thickness is
2.0±0.2mm.
Bolt:
11
Jolywood (Taizhou) Solar Technology Co.,Ltd.
Kaiyang Rd., Jiangyan Economic Development zone, Taizhou City, Jiangsu Province, P. R. China
www.jolywood.cn
+86-523-8061 2361
All module frames and brackets must
be properly grounded in accordance with
the appropriate National Electrical Code.
The grounding conductor or grounding
5.5
Grounding
Mounted with 4 inner holes along the long frame.
C-shaped steel parallel to the long frame.
Maximum load: front ≤2400pa back ≤2400pa
Mounted with 4 inner holes along the long frame.
C-shaped steel perpendicular to the long frame.
Maximum load: front ≤5400pa back ≤2400pa