background image

D-308495 PGP914 Rev.0

 

 

Wall tamper is required for UL/ULC commercial burglary and residential fire installations.

 

a.

 

To mount the bracket on a flat surface, screw the mounting bracket to the wall. See A in 
the following figure.

 

 

Figure 9: Flat bracket screw installation

 

 

 

 

b.

 

Ensure the corner bracket plug is attached. See B in the following figure. To mount 
the bracket on a corner see C or D in the figure below. C is for without back tamper 
protection, and D is for with back tamper protection.

 

 

Figure 10: Corner bracket screw installation

 

 

 

Callout

 

Component

 

A

 

Flat surface mounting

 

B

 

Corner bracket with plug

 

C

 

Corner bracket with back tamper

 

D

 

Corner bracket without back tamper

 

E

 

Stopper snap

 

F

 

Break-away segment

 

2.

 

Align the device with the bracket. See A1 in the following figure.

 

3.

 

Slide the device upward until a click is heard. See A2 and A3 in the following figure.

 

 

 

 

 

PGP914 Wireless PIR Motion Detector Installation Guide 

9

 

Содержание PGP914

Страница 1: ...nly Important Checkthedevice andtheentirealarm system weekly toensure optimal performance Note TocomplywithFCCandISEDCanadaRFexposurecompliancerequirements locate the device at a distance of at least 20 cm from all persons during normal operation Do not co locate the antennas used for this product or operate them in conjunction with any other antenna or transmitter Figure 1 PGP914 Callout Descript...

Страница 2: ...is not available or if the device does not automatically enroll open the device cover to trigger the enrollment Alternatively press the enroll button until the yellow LED light turns on 4 If requested enter the PIN code printed on the device label 5 To manually enroll the device a Scan the QR Code on the device box using the IQ4 camera if available or see step b b Manually enter the device ID prin...

Страница 3: ...l uated by UL ULC Define whether or not the control panelwillreport a very hot alert when the temperature rises above the threshold value for at least the Alert Delay duration value Alert restore will occur when the temperature drops 1 C 1 8 F below the threshold for at least the Restore Delay duration Note The default threshold value for very hot is 35 C 95 F Optional settings See Configuring the...

Страница 4: ...e default threshold value for freezing is 7 C 45 F Optional settings See Configuring the Temperature Alerts FREEZER 10 C 14 F Define whether or not the control panel will report a freezer alert when the temperature rises above the threshold value for at least the Alert Delay duration Alert restore will occur when the temperature drops 1 C 1 8 F below threshold for at least the Restore Delay durati...

Страница 5: ...alert delay time values are Immediately 1 min 2 min 10 min default 15 min 20 min 30 min Restore delay Define the amount of time the panel waits before an alert is reported when the temperature exceeds the defined default The restore delay time values are Immediately 1 min 2 min 10 min default 15 min 20 min 30 min Opening and closing the device cover 1 Toopen the device cover loosen the cover screw...

Страница 6: ...ove Do not install the pet mask if you are mounting the device at this height or above 1 Insert the tabs at the base of the pet mask into the holes below the PIR sensor See A1 in the following figure 2 Align the tabs on the sides of the pet mask with the holes on either side of the PIR sensor See A2 in the followingfigure 3 Press down gently to install the pet mask Figure 5 Installing the Pet Mask...

Страница 7: ...s below the PIR sensor See A2 in the following figure 4 Gently lift the petmask Figure 6 Removing the Pet Mask 5 Close the device cover See Figure 4 Mounting the device using tape 1 Ensure the plug is attached to the back of the corner bracket See Figure 9 2 Peel the release liners off the two strips of double sided adhesive tape and attach the tape to the back of the bracket See Figure 7 Use opti...

Страница 8: ...e 8 Attaching the device to the bracket Mounting the device using screws About this task Note Mounting using screws is required for UL ULC commercial burglary and residential fire type installations Wall tamper break away segment shall also be enabled 1 Screw the bracket onto the wall Note Make sure to fasten the break away segment to the frame If the device is forcibly removed from the wall this ...

Страница 9: ...t on a corner see C or D in the figure below C is for without back tamper protection and D is for with back tamper protection Figure 10 Corner bracket screw installation Callout Component A Flat surface mounting B Corner bracket with plug C Corner bracket with back tamper D Corner bracket without back tamper E Stopper snap F Break away segment 2 Align the device with the bracket See A1 in the foll...

Страница 10: ...the bracket Replacing the battery Note The device transmits a low battery signal upon detection of low voltage It is recommended to wait about 1 minute after battery removal before inserting the new battery CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the manufacturer s instructions and according to local rules and regulations 1 Remov...

Страница 11: ...tart the test remove the device cover from the base See Figure 3 2 Close the cover to return the tamper switch to its normal position 3 The device enters a 2 minute stability period During this time the red LED blinks 4 Walk test the coverage area See the figure below Walk across the far end of the coverage pattern in both directions The red LED lights each time your motion is detected followed by...

Страница 12: ...eceived in regions requiring UL compliant installation only strong signal strength ispermitted Note It is recommended to have a strong signal strength and you must verify the signal strength using the control panel s diagnostic test For detailed Diagnostics Test instructions refer to the control panel installer guide Figure 14 Coverage pattern walk test 12 PGP914 Wireless PIR Motion Detector Insta...

Страница 13: ...t evaluated by UL ULC Low Battery Threshold 2 4 V at room temperature 25 C 77 F Nominal Operating Voltage Operating Temperature 10 C 14 F to 50 C 122 F UL verified range 0ºC 32 F to 49ºC 120 F only Storage Temperature 20 C 4 F to 60 C 140 F Relative Humidity Up to 95 non condensingFor UL installations 5 to 93 with no condensation Dimensions LxWxD 86 mm x 63 mm x 40 mm 3 4 in x 2 5 in x 1 6 in Weig...

Страница 14: ...ever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Страница 15: ...any other disturbances which may cause false alarms No vertical adjustment is needed Motion event counter determines whether one high sensitivity or two low sensitivity consecutive motion events trigger an alarm Very low current consumption Microprocessor controlled temperature compensation Front and back tamperprotection Temperature sensing and reporting Remote firmware upgrade Limited Warranty D...

Страница 16: ... You under the terms of that license agreement By installing copying downloading storing accessing or otherwise using the SOFTWARE PRODUCT You agree unconditionally tobe boundbythe terms ofthis EULA evenifthis EULAis deemed to be a modification of any previous arrangement or contract If You do not agree to the terms of this EULA DSC is unwilling to license the SOFTWARE PRODUCT to You and You have ...

Страница 17: ...the SOFTWARE PRODUCT including but not limited to any images photographs and text incorporated into the SOFTWARE PRODUCT the accompanying printed materials and any copies of the SOFTWARE PRODUCT are owned by DSC or its suppliers You may not copy the printed materials accompanying the SOFTWARE PRODUCT All title and intellectual property rights in and to the content which may be accessed through use...

Страница 18: ...Y OR TO CHANGE THIS WARRANTY NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT e EXCLUSIVE REMEDY AND LIMITATION OFWARRANTY UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY OR ANY OTHER LEGAL THEORY SUCH DAMAGES INCLUDE BUTARENOTLIM...