D-308495 PGP914 Rev.0
FCC (912 to 919 MHz)
: 47CFR part 15
ISED (912 to 919MHz)
: RSS-247
UL/ULC
: UL 639, ULC S306
PGP914
Fresnel and cylinder type lens with optical attenuation (pet mask) in the lower pattern part of
the lens. Number of beams / curtains: 27 Fresnel far (54 sensitivity
“beams”),
18 Cylinder mid,
10 Cylinder close.
Important!
Instruct the user to walk test at least once a week to verify proper function of the
device.
After installation verify the product functionality with the compatible receivers HSM2HOST9,
HS2LCDRF (P)9, HS2ICNRF(P) 9, PG9920 and WS900- 29, WS900-19.
Specifications
Frequency band
912 to 919 MHz
Modulation
GFSK
Communication Protocol
PowerG
Battery Type
3 V Lithium CR-123A Panasonic, Duracell, and GP only
Battery Life
6 to 8 years with typical use at room temperature 25°C (77°F)
Note:
Not evaluated by UL/ULC.
Low Battery Threshold
2.4 V at room temperature 25°C (77°F)
Nominal Operating Voltage
Operating Temperature
-
10°C
(14°F)
to
50°C
(122°F).UL
verified range:
0ºC
(32°F)
to
49ºC
(120°F )
only
Storage Temperature
-
20°C (
-
4°F) to 60°C (140°F)
Relative Humidity
Up to 95% non-condensingFor UL installations: 5 % to 93 % with
no condensation.
Dimensions (LxWxD)
86 mm x 63 mm x 40 mm (3.4 in. x 2.5 in. x 1.6 in.)
Weight (including battery)
85 g (3 oz)
UL/ULC Installation
Mounting the device at a height lower than 2.4 m (8 ft) may
reduce the maximum range of the detector. The dead zone in
UL/ULC installation is up to 2.4 m (8 ft).
Max. coverage
12 x 12 m (39 x 39 ft) /
90°
Pet immunity
Up to 38 kg (85 lb)
Color
White
Compliance with standards
The PGP914 complies with the following standards:
FCC and ISED Canada Compliance Statement
This device complies with FCC Rules Part 15 and with ISED license-exempt RSS standard(s).
Operation is subject to two conditions:
PGP914 Wireless PIR Motion Detector Installation Guide
13