Installation
Warning! Refer to Safety
chapters.
Technical data
Dimensions
Height
894 - 912 mm
Width
600 mm
Depth
600 mm
Location of the appliance
You can install your freestanding appliance with
cabinets on one or two sides and in the corner.
Minimum distances
Dimension
mm
A
685
Levelling of the appliance
Use small feet on the bottom of appliance to set
the appliance top surface level with other
surfaces.
Electrical installation
Warning! The manufacturer
is not responsible if you do
not follow the safety
precautions from Safety
chapters.
This appliance is supplied without a main plug or
a main cable.
Applicable types of cables for different phases:
Phase
Min. size cable
1
3x10.0 mm²
3 with neutral
5x1.5 mm²
Warning! The power cable
must not touch the part of
the appliance shaded in the
illustration.