 Joerns

®

 Bariatric Beds

 

 Bari10A Model

3

Warning: Possible Injury Or Death.

 If using 

accessories not manufactured, marketed, or 

provided by Joerns Healthcare for Joerns

®

 beds, 

consult with the manufacturer for compatibility and 
limitations prior to use. Failure to do so may result in 
injury or death.

Warning: Possible Shock Hazard.

 Bed power 

cord has hospital-grade, 3-pronged grounded plug. 

Grounding reliability can only be achieved when 
equipment is connected to an equivalent receptacle 
marked hospital-grade. If external grounding 

conductor is in doubt, operate bed from backup 

battery. Failure to do so could result in injury. 

Warning: Possible Equipment Damage Or 
Injury To Staff Members. 

Service and repair must 

only be performed by qualified, authorized Joerns 

Healthcare Technical Support personnel  
(call 

800-966-6662

).

Warning: Explosion Hazard.

 

Do not

 use in 

the presence of flammable anesthetics, gas or 

vapors. Failure to heed this warning could result in 

equipment damage, injury or death. 

Caution:

 Stay clear of underneath the bed when 

adjusting or moving the bed. 

Caution:

 Mattress Support Platform is not grounded, 

nor does it have a potential equalization connection 

point. To prevent injury to resident/patient connected 

to intravascular or intercardial medical equipment, 
alternate measure must be implemented to equalize 

the potential between Mattress Support Platform and 
medical equipment. 

Warning: 

To reduce the risk of injury, ensure the 

sleep surface is horizontal and in the lowest position 

with the siderails fully raised and locked when 
moving the bed with a resident/patient in it. For best 

maneuverability performance, push the bed from the 

head end.

To avoid injury to the resident/patient and/or user, do 

not attempt to move the bed laterally with the steer 
mode engaged. The steer wheel can not swivel.

Caution: 

To avoid damage to the siderail 

mechanisms, do not move the bed using the 

siderails. Use the push/pull handles integrated to the 
end panels to move the bed.

Caution: 

Before transporting bed, unplug bed 

from power source, route Power Cord around Cord 

storage hooks on bed frame below Head Panel 

and hang Pendant Cord from Foot Panel. Failure 
to do so could result in Power Cord, Pendant 
Cord or bed damage, thereby creating a potential 
hazard. Failure to do so could result in Power 
cord, Pendant Cord or bed damage, thereby 
creating a potential hazard. 

Caution: 

Particular precaution must be considered 

during exposure to strong emission source such 
as High Frequency surgical equipment and  
similar devices. Do not route High Frequency 

cables on or near device. If in doubt, contact a 
qualified technician. 

When assessing the risk for entrapment, you need 
to consider your bed, mattress, Head/Foot Panels, 
Side Rails/Assist Device and other accessories, 

as a system. It is also extremely important to 
review the resident/patient’s physical and mental 
condition and initiate an appropriate individual care 
plan to address entrapment risk. All Joerns bed 
systems are evaluated for compliance to the  

FDA/CDRH “Hospital Bed System Dimensional 

and Assessment Guidance to Reduce 

Entrapment.” For more information, call Customer 
Care, 800-826-0270.

Save These Instructions 

Thank you

 and congratulations for choosing the 

Joerns Bari10A bed. Joerns beds are developed 

with safety, comfort and convenience of both 

resident/patients and caregivers in mind. 

Advanced ergonomic design will provide years of 
reliable service in your facility.

Содержание Bari10A

Страница 1: ...Joerns Healthcare User Service Manual Joerns Model Bari10A Bariatric Bed leading bed evolution To avoid injury read user s manual before using bed...

Страница 2: ...not be placed in an oxygen enriched environment such as an oxygen tent Use of electrical circuits in an oxygen enriched environment could result in a fire hazard 2 Warning Possible Shock Hazard Unplu...

Страница 3: ...maneuverability performance push the bed from the head end To avoid injury to the resident patient and or user do not attempt to move the bed laterally with the steer mode engaged The steer wheel can...

Страница 4: ...f long term care beds and a frontrunner in addressing this critical issue Joerns Healthcare can offer you the expertise assistance and products to bring your facility into compliance Joerns Compliance...

Страница 5: ...ra 8 length for taller residents patients 18 3 4 to 33 3 4 Travel Range Integrated Scale System for resident patient weight monitoring Head and Foot End Side Rails Assist Devices Side Rails on Head an...

Страница 6: ...Lock for all functions to keep bed from accidentally operating using battery backup Note To avoid electric shock always plug bed into properly grounded hospital grade receptacle Actuator battery backu...

Страница 7: ...port Platform Release Lever Up Hold Emergency Release handle Up until Mattress Support Platform lowers to desired position Release handle if you need to stop descent 1 1 1 2 7 Figure 4 Bari Selective...

Страница 8: ...s rotate switch until it clicks into position Side Rails Assist Devices Bari10A has one Head end Side Rail and one Foot end Side Rail on both sides of bed Figure 7 Side Rails are attached and operated...

Страница 9: ...owest position with the siderails fully raised and locked when moving the bed with a resident patient in it For best maneuverability performance push the bed from the head end Warning 5th wheel must b...

Страница 10: ...p process Slide the Frame Extender out first by pulling out the latch knob on the side of the bed frame Figure 14 Begin carefully sliding the extender out and release the latch knob as soon as the ext...

Страница 11: ...t to lock all four casters individually to prevent unintended bed movement Always plug bed back into power outlet so that it is continuously charging Accessories Mattress Bari10A Bed may be equipped w...

Страница 12: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 12 F Figure 18...

Страница 13: ...ng Conditions Ambient Temperature 20 C to 30 C Relative Humidity 10 to 95 Non Condensing Storage and Shipping Conditions Ambient Temperature 30 C to 50 C Relative Humidity 10 to 95 Non Condensing 1 2...

Страница 14: ...will lose all stored resident patient s weight history Pressing Weight Mode button will switch back to the Weight Mode allowing you to view resident patient s total weight again Caution If you do not...

Страница 15: ...12 months or as your maintenance policy requires Electrostatic Discharge ESD Integrated circuits and semiconductors on printed circuit boards may be damaged by electrostatic discharge ESD Be sure to...

Страница 16: ...teries 1 2 3 1 2 3 4 Battery Replacement If Scale System batteries need replacement display will indicate CHANGE BATTERIES Remove Battery Cover from Foot Panel to access Scale System batteries Figure...

Страница 17: ...Use Super Lube synthetic grease or equivalent Oiling Points Keep pins and bolts oiled sample indicated by arrows in Figure 24 Oil hinge points sample indicated by arrows in Figure 25 Grease Points For...

Страница 18: ...d may be damaged Check cord for damage If cord is damaged discontinue bed usage until cord is replaced 1 2 3 4 If Adjustment Only partially occurs stops and beeps Battery may be low Plug bed into powe...

Страница 19: ...ctions may require two hands to apply equal pull force Contact Joerns Healthcare Technical Support at 800 966 6662 1 2 Mattress Support Platform sections do not articulate Pendant Control operation Se...

Страница 20: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 20 Appendix A Actuator Wiring Diagram...

Страница 21: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model Appendix B Scale System Wiring Diagram 21...

Страница 22: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 22 Notes...

Страница 23: ...www joerns com info joerns com Joerns Bariatric Beds Bari10A Model 23 Notes...

Страница 24: ...mal use These parts such as DC batteries are not covered under the one year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to...

Отзывы: